Current Transducer
Current Transducer HX 02..06-P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolatio...
Description
Current Transducer HX 02..06-P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 2 .. 6 A
Electrical data
Primary nominal current rms IPN (A)
Primary current measuring range
IPM (A)
2 4 6
± 6 ± 12 ± 18
All data are given with RL = 10 kW
Primary conductor
Type
diameter x turns
(mm)
0.5d x 30T 0.7d x 15T 1.0d x 10T
HX 02-P HX 04-P HX 06-P
VOUT ROUT RL VC VC
Output voltage (Anarog) @ ± IPN, RL = 10 kW, TA = 25 °C Output internal resistance
Load resistance
Supply voltage (± 5 %) 1)
Current consumption
Accuracy - Dynamic performance data
± 4 < 50 ≥ 10 ± 15 < ± 15
V W
kW V
mA
εX Accuracy @ IPN , TA = 25°C (xcluding offset) L Linearity error (0 .. ± IPN)
< ± 1 % of IPN < ± 1 % of IPN
VOE Electorical offset voltage @ IP = 0, TA = 25°C
< ± 40 mV
VOH Hysteresis offset voltage @ IP = 0
after an excursion of 1 x IPN
< ± 15 mV
TCVOE Temperature coefficient of VOE
< ± 1.5 mV/K
TCVOUT Temerature coefficient of VOUT (% of reading)
± 0.1 %/K
tr Response time to 90% of IPN step
≤ 3
µs
BW Frequency bandwidth (- 3 dB) 2)
50 kHz
General data
TA Ambient operating temperature
TmS
Ambient storage temperature
Mass
...
Standards
- 25 .. + 85
°C
- 25 .. + 85
°C
8
g
EN 50178: 1997
Note: 1) Also o...