HX04-P

LEM

Current Transducer

Current Transducer HX 02..06-P For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolatio...


LEM

HX04-P

File Download Download HX04-P Datasheet


Description
Current Transducer HX 02..06-P For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 2 .. 6 A Electrical data Primary nominal current rms IPN (A) Primary current measuring range IPM (A) 2 4 6 ± 6 ± 12 ± 18 All data are given with RL = 10 kW Primary conductor Type diameter x turns (mm) 0.5d x 30T 0.7d x 15T 1.0d x 10T HX 02-P HX 04-P HX 06-P VOUT ROUT RL VC VC Output voltage (Anarog) @ ± IPN, RL = 10 kW, TA = 25 °C Output internal resistance Load resistance Supply voltage (± 5 %) 1) Current consumption Accuracy - Dynamic performance data ± 4 < 50 ≥ 10 ± 15 < ± 15 V W kW V mA εX Accuracy @ IPN , TA = 25°C (xcluding offset) L Linearity error (0 .. ± IPN) < ± 1 % of IPN < ± 1 % of IPN VOE Electorical offset voltage @ IP = 0, TA = 25°C < ± 40 mV VOH Hysteresis offset voltage @ IP = 0 after an excursion of 1 x IPN < ± 15 mV TCVOE Temperature coefficient of VOE < ± 1.5 mV/K TCVOUT Temerature coefficient of VOUT (% of reading) ± 0.1 %/K tr Response time to 90% of IPN step ≤ 3 µs BW Frequency bandwidth (- 3 dB) 2) 50 kHz General data TA Ambient operating temperature TmS Ambient storage temperature Mass ... Standards - 25 .. + 85 °C - 25 .. + 85 °C 8 g EN 50178: 1997 Note: 1) Also o...