Document
www.eicsemi.com
TH97/2478
TH09/2479
IATF 0113686 SGS TH07/1033
DB101 - DB107
MINI-BRIDGE RECTIFIERS
PRV : 50 - 1000 Volts Io : 1.0 Ampere
DFM
0.255(6.5) 0.245(6.2)
~~
FEATURES :
* High current capability * High surge current capability * High reliability * Low reverse current * Low forward voltage drop * Ideal for printed circuit board * Pb / RoHS Free
MECHANICAL DATA :
* Case : Molded plastic * Epoxy : UL94V-0 rate flame retardant * Terminals : Leads solderable per MIL-STD-202,
method 208 guaranteed * Mounting position : Any * Weight : 0.02 ounce, 0.4 gram
0.346(8.8) 0.307(7.8)
0.126(3.2) 0.102(2.6) Max.0.02(0.5)
0.165(4.2) 0.155(3.9)
0.205(5.2) 0.195(5.0)
0.350(8.9) 0.300(7.6)
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25°C ambient temperature unless otherwise specified. 60 Hz, resistive or inductive load.
RATING
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Output Rectified Current at Ta = 40°C Peak Forward Surge Current 8.3 ms single half sine wave superimposed on rated load (JEDEC Method) Maximum Instantaneous Forward Voltage per element at IF = 1.0 A Maximum DC Reverse Current Ta = 25°C at Rated DC Blocking Voltage Ta = 125°C Junction and Storage Temperature Range
SYMBOL DB101 DB102 DB103 DB104 DB105 DB106 DB107 UNIT
VRRM VRMS VDC
50 100 200 400 600 800 1000 V
35
70 140 280 420 560 700 V
50 100 200 400 600 800 1000 V
IF(AV)
1.0
A
IFSM
40
A
VF
1.1
V
IR
5.0
µA
IR(H)
500
µA
TJ, TSTG
- 55 to + 150
°C
Page 1 of 2
Rev. 03 : September 8, 2010
www.eicsemi.com
TH97/2478
TH09/2479
IATF 0113686 SGS TH07/1033
RATING AND CHARACTERISTIC CURVES ( DB101 - DB107 )
AVERAGE FORWARD OUTPUT CURRENT, AMPERES
FIG.1 - DERATING CURVE FOR OUTPUT RECTIFIED CURRENT
1.0
0.8
0.6
0.4 60Hz RESISTIVE OR INDUCTIVE LOAD
0.2
00
25
50
75
100 125 150 175
AMBIENT TEMPERATURE, ( °C)
PEAK FORWARD SURGE CURRENT, AMPERES
FIG.2 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT PER BRIDGE ELEMENT
50
40
30
20
SINGLE SINE-WAVE
10
(JEDEC METHOD)
01 2
4 6 10 20 40 60 100
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
10
FIG.4 - TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT
10
REVERSE CURRENT, MICROAMPERES
1
Pulse Width = 300 µs 2% Duty Cycle
0.1
TJ = 25 °C
0.01 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
FORWARD VOLTAGE, VOLTS
1.0
0.1
TJ = 25 °C
0.0 0
20 40
60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FORWARD CURRENT, AMPERES
Page 2 of 2
Rev. 03 : September 8, 2010
.