Document
GLASS PASSIVATED SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 8.0 Amperes
RL801K THRU
RL807K
FEATURES
* Low leakage * Low forward voltage drop * High current capability * High surge capability * High reliability
MECHANICAL DATA
* Case: D-PAK molded plastic * Epoxy: Device has UL flammability classification 94V-O * Lead: MIL-STD-202E method 208C guaranteed * Mounting position: Any * Weight: 0.33 grams
.264 (6.7) .248 (6.3) .217 (5.5) .201 (5.1)
PIN3
.051 (1.3) .035 (0.9)
D-PAK
.098 (2.5) .083 (2.1)
.024 (0.6) .016 (0.4)
PIN1
PIN2
.244 (6.2) .228 (5.8) .398 (10.11) .382 (9.71) TYP 1.00
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYP .091 (2.30)
.183 (4.65) .179 (4.55)
.031 (0.8) .016 (0.4)
PIN 1
PIN 3
TYP .020 (0.50)
PIN 2
HEATSINK
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TC = 100 oC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time
SYMBOL VRRM VRMS VDC IO
IFSM I2t
RL801K 50 35 50
RL802K 100 70 100
RL803K 200 140 200
RL804K RL805K
400
600
280
420
400
600
RL806K 800 560 800
RL807K 1000 700 1000
8.0
125 64.8
Typical Thermal Resistance (Note 1)
Typical Junction Capacitance (Note 2) Operating and Storage Temperature Range
RQ JC RQ JA
CJ TJ, TSTG
3.6 25 40 -55 to + 150
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL RL801K
Maximum Instantaneous Forward Voltage at 8.0A DC
VF
Maximum DC Reverse Current at Rated DC Blocking Voltage
@TA = 25oC @TA = 100oC
IR
NOTES :
1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
4. Suffix "R" for Reverse Polarity. 5. Suffix "S" for D2-PAK Pkg. 6. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
RL802K RL803K
RL804K RL805K 1.0
1.0 50
RL806K RL807K
UNITS Volts Volts Volts Amps
Amps A2/S
0C/W
pF 0C
UNITS Volts
uAmps 2016-09 REV:A
RATING AND CHARACTERISTICS CURVES ( RL801K THRU RL807K )
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (MA)
INSTANTANEOUS FORWARD CURRENT, (A)
10
40
20
8
10
6
4
4
2
Single Phase Half Wave 60 Hz Inductive or
Resistive Load
0 0
1000
50
100
150
CASE TEMPERATURE, (OC)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
100
TA = 100 OC
10
TA = 25 OC 1.0
0.1 0 20 40 60 80 100 120 140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
CT, JUNCTION CAPACITANCE, (pF)
1.0
0.4
TA = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0.1 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.2 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
200
100 60 40 20 10
6 4
2 TJ = 25 OC
0 0.1 0.2 0.4
1.0 2 4
10 20 40 100
REVERSE VOLTAGE, (V)
FIG.4 TYPICAL JUNCTION CAPACITANCE
PEAK FORWARD SURGE CURRENT, (A)
150
8.3mS Single Half Sine-Wave
125
JEDEC Method
100 75
50
25
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
Marking Description
Rectron Logo Part No.
VYWW
RL80X
Year – code (Y:Last digit of year &
A:2010,B:2011……)
Week – code (WW:01~52)
Voltage-code
1-------50V 5-------600V 2-------100V 6-------800V 3-------200V 7------1000V 4-------400V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE D-PAK
PACKING CODE -C
EA PER BOX 2,000
INNER BOX SIZE (mm)
550*140*92
CARTON SIZE (mm)
572*308*120
EA PER CARTON 4,000
WEIGHT(Kg) 10.20
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk.