Document
SURFACE MOUNT SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
SA1L THRU SA7L
FEATURES
* Ideal for surface mounted applications * Low leakage current * Metallurgically bonded construction * Mounting position: Any * Weight: 0.016 gram
SOD-123FL
MECHANICAL DATA
* Epoxy : Device has UL flammability classification 94V-0
.035 (0.90) .028 (0.70)
.114 (2.9) .106 (2.7)
.077 (1.95) .069 (1.75)
.008 (0.20)
.039 (1.00) .035 (0.90)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. resistive or inductive load.
.150 (3.8) .142 (3.6)
.052 (1.32) .050 (1.28)
.033 (0.85) .030 (0.75)
.044 (1.12) .043 (1.08)
.033 (0.85) .030 (0.75)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA = 55oC Peak Forward Surge Current IFM(surge): 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Current Squarad Time
Typical Thermal Resistance (Note 3)
Typical Junction Capacitance (Note 1) Operating and Storage Temperature Range
SYMBOL VRRM VRMS VDC IO
IFSM
I2t
R1JA R1JL CJ TJ, TSTG
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage at 1.0A DC
VF
Maximum DC Average Reverse Current at Rated DC Blocking Voltage
@TA = 25oC @TA = 100oC
IR
NOTES : 1. Measured at 1.0 MHz and applied average voltage of 4.0VDC
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Thernal Resistance: Mounted on PCB. 4. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
SA1L 50 35 50
SA2L 100 70 100
SA3L 200 140 200
SA4L 400 280 400 1.0
30
SA5L 600 420 600
2.5 85 25 8 -55 to + 150
SA6L 800 560 800
SA7L 1000 700 1000
UNITS Volts Volts Volts Amps
Amps
A2/Sec
0 C/W 30
pF
0C
SA1L
SA2L
SA3L
SA4L 1.0 1.0 50
SA5L
SA6L
SA7L UNITS
Volts uAmps uAmps
2015-02 REV:B
RATING AND CHARACTERISTICS CURVES ( SA1L THRU SA7L )
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
1.0
50
8.3ms Single Half Sine-Wave
(JEDED Method)
0.8
40
0.6
30
0.4
Single Phase Half Wave 60Hz 0.2 Resistive or Inductive Load
0
250
50 75
100 125 150 175
AMBIENT TEMPERATURE, (OC)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
10
1.0
20
10
0
0
2
4
86 10 20 40 60 80 100
NUMBER OF CYCLES AT 60Hz
FIG.2 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
100
40 TA = 100 OC
10
INSTANTANEOUS REVERSE CURRENT, (MA)
4
TA = 100 OC
0.1
1.0 TA = 25 OC
Pulse Width = 300ms 1% Duty Cycle
0.01
0
0.5 1.0 1.5
2.0
2.5 3.0
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
0.4
0.1 0 20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.4 TYPICAL REVERSE CHARACTERISTICS
JUNCTION CAPACITANCE, (pF)
200 TA = 25 OC
100
60 40
20
10 6 4
2
1 0.20.1 0.4
21.0 4 10 20 40 100
REVERSE VOLTAGE, (V)
FIG.5 TYPICAL JUNCTION CAPACITANCE
Mounting Pad Layout
.052 MIN. (1.32 MIN.)
.033 MIN. (0.85 MIN.)
.044 MIN. (1.12 MIN.)
0.165 (4.19) REF
Dimensions in inches and (millimeters)
.033 MIN. (0.85 MIN.)
Marking Description
Cathode Band
SA X YW
Year – code (Y: Last digit of year&
A: 2010, B:2011……)
Part No.
Voltage-code
1-------50V 5-------600V 2-------100V 6-------800V 3-------200V 7-------1000V 4-------400V
Week – code (W: A----week 01~02,
B----week 03~04, C----week 05~06,
ĂĂ
Z----week 51~52)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
REEL PACK
PACKAGE PACKING EA PER CODE REEL
SOD-123F/ SOD-123FL
-W
3,000
EA PER INNER BOX
COMPONENT SPACE (mm)
TAPE SPACE (mm)
REEL DIA (mm)
CARTON SIZE (mm)
EA PER CARTON
GROSS WEIGHT(Kg)
15,000
---
---
178 390*205*31 120,000 6.964
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and sh.