HIGH VOLTAGE ASSEMBLIED RECTIFIER
HIGH VOLTAGE ASSEMBLIED RECTIFIER
VOLTAGE RANGE 15000 Volts CURRENT 0.35 Amperes
FEATURES
* Low cost * Low leakage * Iso...
Description
HIGH VOLTAGE ASSEMBLIED RECTIFIER
VOLTAGE RANGE 15000 Volts CURRENT 0.35 Amperes
FEATURES
* Low cost * Low leakage * Isolated case * Surge overload rating - 50 amperes peak * Mounting position: Any * Low forward voltage drop
H V M 1 5L
HVML
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
MAXIMUM RATINGS (At TA = 25oC unless otherwise noted) RATINGS
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current at TA = 50oC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Operating and Storage Temperature Range
SYMBOL VRRM VRMS VDC IO
IFSM TJ,TSTG
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS Maximum Instantaneous Forward Voltage at 0.35A DC Maximum DC Reverse Current at Rated DC Blocking Voltage
NOTES:1. Enough heat sink must be considered in application. 2. Operating and Storage Temperature : -20oC to +150oC 3. Suffix “ L “ for Wire type.
SYMBOL VF
IR
Dimensions in inches and (millimeters)
HVM15L 15 10.5 15 350
50 -20 to + 150
HVM15L 14.0 5.0
UNITS K Volts K Volts K Volts mAmps
Amps 0C
UNITS Volts uAmps 2 013-09 REV: A
AVERAGE FORWARD CURRENT, (mA)
RATING AND CHARACTERISTIC CURVES ( HVM15L)
FIG. 1 - TYPICAL FORWARD CURRENT DERATING CURVE
500
400
S...