FEATURES ·With TO-220AB insulated package ·Suitables for general purpose AC switching . which can be used as an
ON/OFF function in applications such as static relays, heating regulation, Induction motor starting circuits or for phase control in light dimmers, motor speed controllers etc. ·Minimum Lot-to-Lot variations for robust device performance and reliable operation
ABSOLUTE MAXIMUM RATINGS(Ta=25℃)
SYMBOL
PARAMETER
MIN
UNIT
VDRM Repetitive peak off-state voltage
600
V
VRRM Repetitive peak reverse voltage
600
V
IT(RMS) RMS on-state current (full sine wave)Tj=105℃
8
A
ITSM Non-repetitive peak on-state current tp=20ms
80
A
Tj
Operating junction temperature
125
℃
Tstg Storage temperature
-45~150 ℃
Rth(j-c) Thermal resistance, junction to case
2.5 ℃/W
Rth(j-a) Thermal resistance, junction to ambient
60
℃/W
ELECTRICAL CHARACTERISTICS (TC=25℃ unless otherwise specified)
SYMBOL
PARAMETER
CONDITIONS
IRRM
Repetitive peak reverse current
VR=VRRM,
VR=VRRM, Tj=125℃
IDRM
Repetitive peak off-state current
VD=VDRM,
VD=VDRM, Tj=125℃
IGT
Gate trigger current Ⅰ-Ⅱ-Ⅲ VD=12V; RL= 30Ω
IH
Holding current
IGT= 0.1A, Gate Open
VGT Gate trigger voltage Ⅰ-Ⅱ-Ⅲ VD=12V; RL= 30Ω
VTM On-state voltage
IT= 11A; tp= 380μs
MAX
0.005 1
0.005 1
35
UNIT
mA mA mA
35
mA
1.3
V
1.55 V
isc website: www.iscsemi.com