Document
isc N-Channel MOSFET Transistor
·DESCRIPTION ·Drain Current ID= 9A@ TC=25℃ ·Drain Source Voltage-
: VDSS= 900V(Min) ·Fast Switching Speed ·100% avalanche tested ·Minimum Lot-to-Lot variations for robust device
performance and reliable operation
·APPLICATIONS ·Switching voltage regulators
·ABSOLUTE MAXIMUM RATINGS(TC=25℃)
SYMBOL
PARAMETER
VALUE
UNIT
VDSS
Drain-Source Voltage (VGS=0)
900
V
VGS
Gate-Source Voltage
±30
V
ID
Drain Current-continuous@ TC=25℃
9
A
ID(puls)
Pulse Drain Current
27
A
Ptot
Total Dissipation@TC=25℃
250
W
Tj
Max. Operating Junction Temperature
150
℃
Tstg
Storage Temperature Range
-55~150 ℃
·THERMAL CHARACTERISTICS
SYMBOL
PARAMETER
Rth j-c Thermal Resistance, Junction to Case
MAX UNIT 0.5 ℃/W
TK9J90E
isc website:www.iscsemi.cn
1 isc & iscsemi is registered trademark
isc N-Channel MOSFET Transistor
·ELECTRICAL CHARACTERISTICS (TC=25℃)
SYMBOL
PARAMETER
CONDITIONS
V(BR)DSS Drain-Source Breakdown Voltage
VGS= 0; ID=10mA
VGS(th) Gate Threshold Voltage
VDS= VGS; ID=0.9mA
VSD
Diode Forward On-Voltage
IS=9A ;VGS= 0
RDS(on) Drain-Source On-Resistance
VGS= 10V; ID=4.5A
IGSS
Gate-Body Leakage Current
VGS= ±30V;VDS= 0
IDSS
Zero Gate Voltage Drain Current
VDS= 720V; VGS= 0
TK9J90E
MIN TYPE MAX UNIT
900
V
2.5
4.0
V
1.7
V
1.3
Ω
±1
µA
10
µA
NOTICE: ISC reserves the rights to make changes of the content herein the datasheet at any time without notification. The information contained herein is presented only as a guide for the applications of our products. ISC products are intended for usage in general electronic equipment. The products are not designed for use in equipment which require specialized quality and/or reliability, or in equipment which could have applications in hazardous environments, aerospace industry, or medical field. Please contact us if you intend our products to be used in these special applications. ISC makes no warranty or guarantee regarding the suitability of its products for any particular purpose, nor does ISC assume any liability arising from the application or use of any products, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
isc website:www.iscsemi.cn
2 isc & iscsemi is registered trademark
.