OptoMOS Relay. CPC1540G Datasheet

CPC1540G Relay. Datasheet pdf. Equivalent


IXYS CPC1540G
INTEGRATED CIRCUITS DIVISION
CPC1540
Single-Pole, Normally Open OptoMOS® Relay
with Integrated Current Limit and Thermal Shutdown
Parameter
Load Voltage
Load Current
On-Resistance (max)
Input Control Current
Rating
350
120
25
2
Units
VP
mArms / mADC
mA
Features
Integrated Active Current-Limit Protection
Thermal Shutdown
Guaranteed Turn-On: 2mA Input Control Current
350VP Blocking Voltage
3750Vrms Input/Output Isolation
Small Surface Mount Package
Low Drive Power Requirements
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Flammability Rating UL 94 V-0
Applications
Telphony hook switch
VoIP gateways, such as VoIP
IP-PBXs
Satellite and cable set-top boxes
V.92 (and other standard) modems
Fax machines
Voicemail systems
Embedded modems for POS terminals,
automated banking, remote metering, vending
machines, security, and surveillance
Instrumentation
Medical equipment—Patient/equipment isolation
Aerospace
Industrial controls
Pin Configuration
AC/DC Configuration
1
+ Control
2
– Control
3
Do Not Use
6
Load
5
Do Not Use
4
Load
DC Only Configuration
1
6
+ Control
2
5
– Control
3
4
Do Not Use
+ Load
– Load
Description
The CPC1540 is a normally open (1-Form-A) Solid
State Relay with an integrated current limit feature
that can replace electromechanical relays while
enhancing the robustness of wireline-interface
applications.
Designed specifically to target the hook switch
telephony market, the CPC1540 has a load voltage
rating of 350V.
The relay is constructed using an efficient infrared
LED for actuation control and an integrated
monolithic die for the switch output. The die,
fabricated in a high-voltage dielectrically isolated
technology, comprises a photodiode array, switch
control with active current limiting circuitry, and
MOSFET switches. Active current-limit circuitry in
the CPC1540 provides a thermal shutdown feature,
offering excellent power-cross immunity for improved
survivability in harsh environments.
These enhancements greatly improve the robustness
of end systems using this device compared to
systems using relays without the integrated current
limit. In addition, the active current limit circuitry
enables the CPC1540 to pass FCC 68.302 and
other regulatory voltage surge requirements when
adequate overvoltage protection is provided. The
CPC1540 relay may be used in both AC and DC
applications.
Approvals
UL Certified Component: File E76270
CSA Certified Component: Certificate 1172007
EN/IEC 60950-1 Certified Component:
Certificate available on our website
Ordering Information
Part #
CPC1540G
CPC1540GS
CPC1540GSTR
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount, Tape & Reel (1000/Reel)
Switching Characteristics of
Normally Open Devices
Form-A
IF
ILOAD
90%
ton
10%
toff
DS-CPC1540-R04
www.ixysic.com
1


CPC1540G Datasheet
Recommendation CPC1540G Datasheet
Part CPC1540G
Description Normally Open OptoMOS Relay
Feature CPC1540G; INTEGRATED CIRCUITS DIVISION CPC1540 Single-Pole, Normally Open OptoMOS® Relay with Integrated Curr.
Manufacture IXYS
Datasheet
Download CPC1540G Datasheet




IXYS CPC1540G
INTEGRATED CIRCUITS DIVISION
CPC1540
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output (60 Seconds)
Operational Temperature
Storage Temperature
1 Derate linearly 3.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Ratings Units
350
VP
5
V
50
mA
1
A
150
mW
800
mW
3750
Vrms
-40 to +85 °C
-40 to +125 °C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Recommended Operating Conditions
Parameter
Load Current, Continuous
Input Control Current
Operating Temperature
Symbol
IL
IF
-
Configuration Min Nominal Max
AC/DC
-
-
120
DC-Only
-
-
250
-
3
5
10
-
-40
-
+85
Units
mArms / mADC
mADC
mA
ºC
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Current Limit
AC/DC Configuration
DC Configuration
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
LED Forward Voltage
Reverse Input Current
Common Characteristics
Input to Output Capacitance
Conditions
Symbol Min
IF=5mA, VL=13V, t=5ms
IF=5mA, VL=6.5V, t=5ms
ILMT
190
360
IF=5mA, IL=120mA
IF=5mA, IL=220mA
VL=350V
12
RON
3
ILEAK
-
IF=5mA, IL=100mA
ton
-
toff
IF=0mA, VL=20V, f=1MHz
CO
-
IL=100mA
IL<1A
IF=5mA
VIN = -5V
IF
-
IF
0.2
VF
0.9
IR
-
VIO=0V, f=1MHz
CIO
-
Typ
225
430
18.2
4.2
-
0.72
0.3
14
0.8
0.6
1.24
-
0.5
Max
Units
285
mA
570
25
6.75
1
A
2
ms
-
pF
2
mA
-
mA
1.5
V
10
A
-
pF
2
www.ixysic.com
R04



IXYS CPC1540G
INTEGRATED CIRCUITS DIVISION
CPC1540
Typical LED Forward Voltage Drop
vs. Temperature
1.5
1.4
1.3
1.2
1.1
1.0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
PERFORMANCE DATA*
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
Typical Turn-On Time
vs. LED Forward Current
(IL=100mA)
TA=85ºC
TA=25ºC
TA=-40ºC
2
4
6
8
10
LED Forward Current (mA)
0.5
0.4
0.3
0.2
0.1
0.0
0
Typical Turn-Off Time
vs. LED Forward Current
(IL=100mA)
TA=85ºC
TA=25ºC
TA=-40ºC
2
4
6
8
10
LED Forward Current (mA)
Typical IF for Switch Operation
vs. Temperature
(IL=100mA)
1.0
0.8
0.6
0.4
0.2
0.0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Typical Turn-On Time
vs. Temperature
(IF=5mA, IL=100mA)
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Typical Turn-Off Time
vs. Temperature
0.40
(IF=5mA, IL=100mA)
0.35
0.30
0.25
0.20
0.15
-40 -20
0 20 40 60
Temperature (ºC)
80 100
On-Resistance vs. Temperature
(IF=5mA, IL=100mA)
25
20
15
10
5
0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
18.26
On-Resistance vs. LED Current
(IL=100mA, TA=25ºC)
18.24
18.22
18.20
18.18
18.16
18.14
0
2
4
6
8
10
LED Forward Current (mA)
Typical Leakage Current
vs. Temperature
(IF=5mA, IL=100mA, VL=350V)
18
16
14
12
10
8
6
4
2
-40 -20
0 20 40 60
Temperature (ºC)
80 100
100
90
80
70
60
50
40
30
20
10
0
Output Capacitance
vs. Applied Voltage
(IF=0mA, f=1MHz)
5
10
15
Applied Voltage (V)
Current Limit vs. Temperature
(IF=5mA)
300
250
200
150
20
-40 -20 0 20 40 60 80 100
Temperature (ºC)
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
For guaranteed parameters not indicated in the written specifications, please contact our application department.
R04
www.ixysic.com
3





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)