Document
isc Triacs
FEATURES ·With TO-220AB(Isolated) non insulated package ·Suitable for general purpose AC switching. Which can be
used as an ON/OFF function in applications such as static relays, heating regulation,induction motor starting circuits. Or for phase control operation in light dimmers, motor speed controllers etc. ·Minimum Lot-to-Lot variations for robust device performance and reliable operation
ABSOLUTE MAXIMUM RATINGS(Ta=25℃)
SYMBOL
PARAMETER
VDRM Repetitive peak off-state voltage
VRRM Repetitive peak off-state voltage
IT(RMS) RMS on-state current (full sine wave) Tc=95℃
ITSM Non-repetitive peak on-state current
Tj Tstg Rth(j-c) Rth(j-a)
Operating junction temperature Storage temperature Thermal resistance, junction to case Thermal resistance, junction to ambient
f=50Hz f=60Hz
ELECTRICAL CHARACTERISTICS (TC=25℃ unless otherwise specified)
SYMBOL
PARAMETER
CONDITIONS
IRRM IDRM
Repetitive peak reverse current Repetitive peak off-state current
VR=VRRM,
VR=VRRM, Tj=110℃
VD=VDRM,
VD=VDRM, Tj=110℃
IGT
Gate trigger current (Ⅰ—Ⅳ) VD=12V; RL= 60Ω
IH
Holding current
IGT= 100mA, Gate Open
VGT Gate trigger voltage all quadrant VD=12V; RL= 60Ω
VTM On-state voltage
IT= 4A; tp= 380μ s
L6004L5
MIN
600 600
4 33 40 -40~110 -40~125 3.6 50
UNIT
V V A
A
℃ ℃ ℃/W ℃/W
MAX UNIT
10 200
uA
10 200
uA
5
mA
10 mA
2
V
1.6
V
isc website:www.iscsemi.com
isc & iscsemi is registered trademark
isc Triacs
L6004L5
NOTICE: ISC reserves the rights to make changes of the content herein the datasheet at any time without notification. The information contained herein is presented only as a guide for the applications of our products. ISC products are intended for usage in general electronic equipment. The products are not designed for use in equipment which require specialized quality and/or reliability, or in equipment which could have applications in hazardous environments, aerospace industry, or medical field. Please contact us if you intend our products to be used in these special applications. ISC makes no warranty or guarantee regarding the suitability of its products for any particular purpose, nor does ISC assume any liability arising from the application or use of any products, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
isc website:www.iscsemi.com
isc & iscsemi is registered trademark
.