2-Electrode Gas Discharge Tube
2-Electrode Gas Discharge Tubes
1:Dimension(mm)
4.5*3.2*2.7mm
1KA Surface Mount
2:Main Applications •Transient Voltage...
Description
2-Electrode Gas Discharge Tubes
1:Dimension(mm)
4.5*3.2*2.7mm
1KA Surface Mount
2:Main Applications Transient Voltage Surge Suppression(TVSS) Cable Telephone Product Modems/Cable Modems Broadband/CATV/Coaxial Protectors Communication Lines
4 Electrical Characteristics
3:Features
100% Lead-Free(RoHs Compliant )
Non-Radioactive
Low capacitance ≤0.5pF
Small size :4.5*3.2*2.7mm
Safety certification:
File number: E505240
Part Number
DC Spark-over Voltage@
Impulse Spark-over
Voltage
100V/S @1KV/μs
HA2R3-75SMD 75V ±25%
<600V
HA2R3-90SMD 90V ±20%
<600V
HA2R3-140SMD 140V ±20% <600V
HA2R3-150SMD 150V ±20% <600V
HA2R3-200SMD 200V ±20% <700V
HA2R3-230SMD 230V ±20% <700V
HA2R3-250SMD 250V ±20% <800V
HA2R3-300SMD 300V ±20% <900V
HA2R3-350SMD 350V ±20% ≤ 1000V
HA2R3-400SMD 400V ±20% ≤ 1000V
HA2R3-420SMD 420V ±20% ≤ 1000V
HA2R3-470SMD 470V ±20% ≤ 1200V
HA2R3-500SMD 500V ±20% ≤ 1200V
HA2R3-600SMD 600V ±20% ≤ 1400V
Specifications are subject to change without notice
HUAAN LIMITED
Insulati on
Impulse Impulse discharg Discharg
Resista nce
e current e Current 300hits
GΩ 8/20μs 8/20μs
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
>1GΩ 1KA
100A
1 www.huaandz.com
Impulse Withstanding Voltage 10hits
10/700μs 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V 4000V
A...