2-Electrode Gas Discharge Tube
2-Electrode Gas Discharge Tubes
1:Dimension(mm)
2.5KA Surface Mount
Φ5*4.4mm
2:Main Applications •PCI Cards protectio...
Description
2-Electrode Gas Discharge Tubes
1:Dimension(mm)
2.5KA Surface Mount
Φ5*4.4mm
2:Main Applications PCI Cards protection Telephone/Fax/Modem protection single line protection ADSL/XDSL Splitter,Power Supply Surge Protection Device/Surge Protector 4 Electrical Characteristics
3:Features
100% Lead-Free(RoHs Compliant )
Non-Radioactive
Low capacitance: ≤1pF
Small size :Φ5x4.4mm
Safety certification:
File number: E505240
Part Number
HA2R5-75HSMD HA2R5-90HSMD HA2R5-140HSMD HA2R5-150HSMD HA2R5-200HSMD HA2R5-230HSMD HA2R5-250HSMD HA2R5-260HSMD HA2R5-300HSMD HA2R5-350HSMD HA2R5-400HSMD HA2R5-420HSMD HA2R5-470HSMD HA2R5-500HSMD HA2R5-600HSMD
DC Spark-over Voltage
@100V/S
75V ±20% 90V ±20% 140V±20% 150V±20% 200V±20% 230V±20% 250V±20% 260V±20% 300V±20% 350V±20% 400V±20% 420V±20% 470V±20% 500V±20% 600V±20%
Impulse Spark-ove r Voltage @100V/μs
≤500V ≤500V ≤500V ≤500V ≤600V ≤600V ≤600V ≤700V ≤800V ≤900V ≤900V ≤900V ≤1100V ≤1100V ≤1300V
Impulse Spark-over
Voltage
@1KV/μs
≤ 600V ≤ 600V ≤ 600V ≤ 600V ≤ 700V ≤ 700V ≤ 700V ≤ 800V ≤ 900V ≤ 1000V ≤ 1000V ≤ 1000V ≤ 1200V ≤ 1200V ≤1400V
Insulation Resistanc e
GΩ
>1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ >1GΩ
Impulse discharge current 8/20μs
10 Times
2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA 2.5KA
Impulse Life
300 hits 10x1000μs
100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A
AC discharge current 50Hz,1s
10times
2.5A 2.5A 2.5A 2....