Feature MM30FU060K1; June 2015 Version 01 MM30FU060K1 600V 30A FRED RoHS Compliant PRODUCT FEATURES APPLICATIONS U.
Manufacture MacMic
Datasheet
Download MM30FU060K1 Datasheet





MacMic MM30FU060K1
June 2015
Version 01
MM30FU060K1
600V 30A FRED
RoHS Compliant
PRODUCT FEATURES
APPLICATIONS
Ultrafast Recovery Time
Freewheeling, Snubber, Clamp
Low Recovery Loss
Inversion Welder
Soft Reverse Recovery Characteristics PFC
Low Leakage Current
Plating Power Supply
Low Forward Voltage
High Surge Current Capability
Ultrasonic Cleaner and Welder
Converter & Chopper
1
2
DESCRIPTION
UPS
FRED from MacMic utilizes advanced processing techniques to achieve
ultrafast recovery times and higher forward current. Its soft recovery
characteristics and high reliability suit for wide industrial applications.
TO220-F
ABSOLUTE MAXIMUM RATINGS
T C =25°C unless otherwise specified
Symbol
Parameter/Test Conditions
Values
VR
VRRM
Maximum D.C. Reverse Voltage
Maximum Repetitive Reverse Voltage
600
IF(AV)
Average Forward Current
TC=70
30
IF(RMS)
RMS Forward Current
TC=70
42
IFSM
Non Repetitive Surge Forward Current TJ=25,t=10ms, 50Hz, Sine
260
PD
Power Dissipation
83
TJ
Junction Temperature
-55 to +150
TSTG
Storage Temperature Range
-55 to +125
Torque To Heat Sink
RecommendedM3
1.1
RthJC
Junction to Case Thermal Resistance
1.5
Weight
2.5
Unit
V
A
W
Nm
/W
g
ELECTRICAL CHARACTERISTICS
T C =25°C unless otherwise specified
Symbol
Parameter/Test Conditions
Min. Typ. Max. Unit
IRM
Maximum Reverse Leakage Current
VR =600V
VR =600V, TJ = 125
10 μA
1 mA
VF
Forward Voltage
IF=30A
IF=30A,TJ=125
trr
Reverse Recovery Time (IF = 1A, dIF/dt = -200A/μs, VR = 30V)
2.0
2.4
V
1.7
20
25 ns
trr
Reverse Recovery Time (IF = 0.5A, IR=1A, IRR = 0.25A)
30
40 ns
trr
Reverse Recovery Time
IF =30A,VR =300V,
35
ns
IRRM
Maximum Reverse Recovery Current
dIF/dt = -200A/μs
3
A
trr
Reverse Recovery Time
IF = 30A,VR =300V,
125
ns
IRRM
Maximum Reverse Recovery Current
dIF/dt = -200A/μs ,TJ=125
6
A
MacMic Science & Technology Co., Ltd.
1
Add#18, Hua Shan Zhong Lu, New District, Changzhou City, Jia ngsu Province, P. R .of China
Tel.+86-519-85163708 Fax+86-519-85162291 Post Code213022 Websitewww.macmicst.com



MacMic MM30FU060K1
MM30FU060K1
60
25
50
125
40
30
20
10
0
0
1
2
3
4
VF(V)
Figure 1. Forward Voltage Drop vs Forward Current
15
25
12
125
9
6
3
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 3. Reverse Recovery Current vs dIF/dt
40
30
DC
20
10
0
25 50 75 100 125 150 175
TC()
Figure 5.Forward current vs Case temperature
200
25
160
125
120
80
40
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 2. Reverse Recovery Time vs dIF/dt
1
25
0.8
125
0.6
0.4
0.2
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 4. Reverse Recovery Charge vs dIF/dt
10
1
0.1
0.01
0.001 0.01 0.1
1
10
Rectangular Pulse Duration (s)
Figure 6.Transient Thermal Impedance
2



MacMic MM30FU060K1
MM30FU060K1
Figure 7. Diode Reverse Recovery Test Circuit and Waveform
Dimensions in (mm)
Figure 8. Package Outline
3





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)