FRED. MMF2X60J120D Datasheet

MMF2X60J120D FRED. Datasheet pdf. Equivalent

MMF2X60J120D Datasheet
Recommendation MMF2X60J120D Datasheet
Part MMF2X60J120D
Description FRED
Feature MMF2X60J120D; June 2017 PRODUCT FEATURES □ Ultrafast Reverse Recovery Time □ Soft Reverse Recovery Characteristics.
Manufacture MacMic
Datasheet
Download MMF2X60J120D Datasheet




MacMic MMF2X60J120D
June 2017
PRODUCT FEATURES
Ultrafast Reverse Recovery Time
Soft Reverse Recovery Characteristics
Low Reverse Recovery Loss
High System Power Density
Popular SOT-227 Package
Version 3
MMF2X60J120D
1200V 60A FRED Module
RoHS Compliant
APPLICATIONS
Inversion Welder
Uninterruptible Power Supply
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
PFC
2
1
3
4
ABSOLUTE MAXIMUM RATINGS(T C =25°C unless otherwise specified)
Symbol
Parameter/Test Conditions
VR
Maximum D.C. Reverse Voltage
VRRM Maximum Repetitive Reverse Voltage
IF(AV) Average Forward Current
TC=70, Per Diode
TC=70, Per Moudle
IF(RMS) RMS Forward Current
TC=70°C, Per Diode
IFSM
Non Repetitive Surge Forward
Current
TJ=45,t=10ms,Sine,peak value
TJ=45,t=8.3ms,Sine,peak value
I2t
For Fusing
TJ=45,t=10ms,Sine,peak value
TJ=45,t=8.3ms,Sine,peak value
PD
Power Dissipation
TJ
Junction Temperature
TSTG
Storage Temperature Range
Visol
Isolation Breakdown Voltage
AC, 50Hz(R.M.S), t=1minute
Torque Module to Sink
RecommendedM4
Torque Module Electrodes
RecommendedM4
RthJC Junction to Case Thermal Resistance(Per Diode )
W eight
Values
1200
60
120
84
500
550
1250
1255
192
-40 to +150
-40 to +125
3000
0.71.1
0.71.1
0.65
26.5
MacMic Science & Technology Co., Ltd.
Add#18, Hua Shan Zhong Lu, New District, Changzhou City, Jiangsu Province, P. R .of China
3
Tel.+86-519-85163708 Fax+86-519-85162291 Post Code213022 Websitewww.macmicst.com
Unit
V
A
A2S
W
V
Nm
Nm
/W
g



MacMic MMF2X60J120D
MMF2X60J120D
ELECTRICAL CHARACTERISTICS (T C =25°C unless otherwise specified)
Symbol
Parameter/Test Conditions
Min.
IRM
Maximum Reverse Leakage Current
VR = 1200V
VR = 1200V, TJ = 125
VF
Forward Voltage
IF=60A
IF=60A,TJ=125
trr
Reverse Recovery Time (IF = 1A, dIF/dt = -200A/μs, VR = 30V)
trr
Reverse Recovery Time
IRRM
Maximum Reverse Recovery Current
trr
Reverse Recovery Time
IF=60A,VR =600V,
dIF/dt =-200A/μs
IF=60A,VR =600V,
IRRM
Maximum Reverse Recovery Current
dIF/dt =-200A/μs ,TJ=125
trr
Reverse Recovery Time
IRRM
Maximum Reverse Recovery Current
IF=60A,VR =600V,
dIF/dt =-1000A/μs ,TJ=125
Typ.
1.8
1.55
42
135
9.5
305
18
225
73.5
Max. Unit
0.5 mA
10
2.35
V
ns
ns
A
ns
A
ns
A
120
25
90
125
60
30
0
0 0.5 1 1.5 2 2.5 3
VFV
Figure 1. Forward Voltage Drop vs Forward Current
100
25
80
125
60
40
20
VR=600V
IF=60A
0
0
200 400 600 800 1000
dIF/dtA/μs
Figure 3. Reverse Recovery Current vs dIF/dt
4
500
25
400
125
VR=600V
IF=60A
300
200
100
0
0
200 400 600 800 1000
dIF/dtA/μs
Figure 2. Reverse Recovery Time vs dIF/dt
12
25
10
125
8
VR=600V
IF=60A
6
4
2
0
0
200 400 600 800 1000
dIF/dtA/μs
Figure 4. Reverse Recovery Charge vs dIF/dt



MacMic MMF2X60J120D
MMF2X60J120D
70
60
DC
50
40
30
20
10
0
25
50
75 100 125 150
TC()
Figure 5. Forward current vs Case temperature
1
0.1
0.01
0.001
0.1
10
Rectangular Pulse Duration(S)
Figure 6. Transient Thermal Impedance
Dimensions in (mm)
Figure 7. Package Outline
5





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)