BUTTERWORTH FOURTH-ORDER LOW-PASS SWITCHED-CAPACITOR FILTERS
D Low Clock-to-Cutoff-Frequency Ratio Error
TLC04/MF4A-50 . . . ± 0.8% TLC14/MF4A-100 . . . ± 1%
D Filter Cutoff Frequen...
Description
D Low Clock-to-Cutoff-Frequency Ratio Error
TLC04/MF4A-50 . . . ± 0.8% TLC14/MF4A-100 . . . ± 1%
D Filter Cutoff Frequency Dependent Only on
External-Clock Frequency Stability
D Minimum Filter Response Deviation Due to
External Component Variations Over Time
and Temperature
D Cutoff Frequency Range From 0.1 Hz
to 30 kHz, VCC ± = ± 2.5 V
D 5-V to 12-V Operation D Self Clocking or TTL-Compatible and
CMOS-Compatible Clock Inputs
D Low Supply-Voltage Sensitivity D Designed to be Interchangeable With
National MF4-50 and MF4-100
TLC04/MF4A-50, TLC14/MF4A-100 BUTTERWORTH FOURTH-ORDER LOW-PASS
SWITCHED-CAPACITOR FILTERS
SLAS021A – NOVEMBER 1986 – REVISED MARCH 1995
D OR P PACKAGE (TOP VIEW)
CLKIN 1 CLKR 2
LS 3 VCC – 4
8 FILTER IN 7 VCC+ 6 AGND 5 FILTER OUT
description
The TLC04/MF4A-50 and TLC14/MF4A-100 are monolithic Butterworth low-pass switched-capacitor filters. Each is designed as a low-cost, easy-to-use device providing accurate fourth-order low-pass filter functions in circuit design configurations.
Each filter features cutoff frequency stability that is dependent only on the external-clock frequency stability. The cutoff frequency is clock tunable and has a clock-to-cutoff frequency ratio of 50:1 with less than ± 0. 8% error for the TLC04/MF4A-50 and a clock-to-cutoff frequency ratio of 100:1 with less than ± 1% error for the TLC14/MF4A-100. The input clock features self-clocking or TTL- or CMOS-compatible options in conjunction with the level shift (LS) terminal.
The TL...