DatasheetsPDF.com

RO-0505S Dataheets PDF



Part Number RO-0505S
Manufacturers RECOM
Logo RECOM
Description DC/DC-Converter
Datasheet RO-0505S DatasheetRO-0505S Datasheet (PDF)

Features Unregulated Converters • Industry standard pinout • 1kVDC/1s or 2kVDC/1s isolation • UL94 V-0 package material • Fully encapsulated • Efficiency up to 85% DC/DC Converter RO Description The RO DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -40°C to +85°C without derating. 1 Watt SIP4 YEAR 3 arrant Single Output RE CTS RE CTS y w ERS CO ERS CO Selection Guide .

  RO-0505S   RO-0505S


Document
Features Unregulated Converters • Industry standard pinout • 1kVDC/1s or 2kVDC/1s isolation • UL94 V-0 package material • Fully encapsulated • Efficiency up to 85% DC/DC Converter RO Description The RO DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -40°C to +85°C without derating. 1 Watt SIP4 YEAR 3 arrant Single Output RE CTS RE CTS y w ERS CO ERS CO Selection Guide Part Number nom. Input Voltage [VDC] RO-xx3.3S (3,4) 3.3, 5,12, 15, 24 RO-xx05S (3,4) 3.3, 5,12, 15, 24 RO-xx09S (3,4) 3.3, 5,12, 15, 24 RO-xx12S (3,4) 3.3, 5,12, 15, 24 RO-xx15S (3,4) 3.3, 5,12, 15, 24 RO-xx24S (3,4) 3.3, 5,12, 15, 24 Output Voltage [VDC] 3.3 5 9 12 15 24 Output Current [mA] 303 200 111 83 66 42 Efficiency typ. (1) [%] 75 78-80 78-80 80-84 80-84 78-85 max. Capacitive Load (2) [µF] 2200 1000 1000 470 470 220 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter COM CONVERT RoHS 2+ compliant 10 from 10 M PLIANT PRODU COM CONVERT REACH compliant M PLIANT PRODU E358085 Model Numbering RO- __ __S/_ Input Voltage Output Voltage “Protection (3)” “Isolation Option (4)” Single Notes: Note3: standard part is without continuous short circuit protection add suffix „/P“ for continuous short circuit protection Note4: add suffix „/H“ for 2kVDC/1s isolation or add suffix „/HP“ for continuous short circuit protection and 2kVDC/1s isolation UL60950-1 certified CAN/CSA-C22.2 No 60950-1 certified EN60950-1 certified IEC60950-1 certified EN55032 compliant CB report Ordering Examples: RO-123.3S/P: 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output with continuous short circuit protection RO-0509S/HP: 5VDC Input Voltage, 9VDC Output Voltage, Single Output with 2kVDC/1s Isolation and continuous short circuit protection www.recom-power.com REV.: 4/2020 ECO-1 RO DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) Series BASIC CHARACTERISTICS Parameter Internal Input Filter Input Voltage Range Minimum Load Internal Operating Frequency Output Ripple and Noise Condition 20MHz BW Min. 0% 50kHz Typ. ±10% 100kHz Max. capacitor 105kHz 100mVp-p Efficiency [%] Efficiency [%] Efficiency vs. Load RO-xx05S 100 90 80 70 60 50 40 30 20 3.305 0505 10 1205 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 100 90 80 70 60 50 40 30 20 10 0 0 RO-xx12S 3.312 0512 1212 10 20 30 40 50 60 70 80 90 100 Output Load [%] Efficiency [%] 100 90 80 70 60 50 40 30 20 10 0 0 10 20 RO-xx15S 30 40 50 60 70 Output Load [%] 3.315 0515 1215 80 90 100 REGULATIONS Parameter Output Accuracy Line Regulation www.recom-power.com Condition low line to high line continued on next page REV.: 4/2020 Value -2.0% typ. / ±5.0% max. ±1.2% of 1.0% Vin typ. ECO-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) Parameter Load Regulation (5) Condition 10% to 100% load 3.3Vout 5Vout 12, 15, 24Vout Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met RO Series Value 20.0% max. 15.0% max. 10.0% max. Tolerance Envelope RO-xx3.3S and RO-xx05S RO-xx12S and RO-xx15S +10% +7% Typical Load Line +5% Vnom -2% -5% +10% +5% Typical Load Line +5% Vnom -2% -5% Output Voltage [%] Output Voltage [%] 10 50 100 Output Load [%] 10 50 100 Output Load [%] Deviation vs. Load 25 RO-xx05S RO-xx12S 25 20 3.305 20 3.312 0505 0512 15 1205 15 1212 Deviation [%] Deviation [%] 10 10 5 5 0 0 -5 -5 -10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] -10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] RO-xx15S 25 20 3.315 0515 15 1215 Deviation [%] 10 5 0 -5 -10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] www.recom-power.com REV.: 4/2020 ECO-3 RO DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) Series PROTECTIONS Parameter Short Circuit Protection (SCP) Isolation Voltage (6) Isolation Resistance Isolation Capacitance Insulation Grade I/P to O/P Type without suffix with suffix “/P” without suffix tested for 1 second rated for 1 minute with suffix tested for 1 second “/H” rated for 1 minute Value 1 second continuous 1kVDC 500VAC/60Hz 2kVDC 1kVAC/60Hz 10GΩ min. 20pF min. / 75pF max. basic (IEC/EN60950-1) functional (IEC/EN60601-1) Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Operating Temperature Range Ma.


STCS1 RO-0505S RO-1205S


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)