AC SMOKE DETECTOR
Data Sheet 26110.4
5349
AC SMOKE DETECTOR WITH INTERCONNECT AND TIMER
TIMER START 1 I/O 2
LOGIC
16 GUARD 2 15 DETEC...
Description
Data Sheet 26110.4
5349
AC SMOKE DETECTOR WITH INTERCONNECT AND TIMER
TIMER START 1 I/O 2
LOGIC
16 GUARD 2 15 DETECT. IN
LOW-V SET 3 TIMER OUT 4
LED 5
OSC. & TIMING
14 GUARD1
13
SENSITIVITY SET
12 OSC. CAP.
+ SUPPLY 6 V DD TIMING RES. 7
FEEDBACK 8
HORN DRIVER
11 HORN 2 10 HORN1 VSS 9 – SUPPLY
Dwg. PC-004
The A5349CA is a low-current, CMOS circuit providing all of the required features for an ionization-type smoke detector. A networking capability allows as many as 125 units to be interconnected so that if any unit senses smoke, all units will sound an alarm. In addition, special features are incorporated to facilitate alignment and test of the finished smoke detector. This device is designed to comply with Underwriters Laboratories Specification UL217.
The internal oscillator and timing circuitry keeps standby power to a minimum by powering down the device for 1.66 seconds and sensing smoke for only 10 ms. Every 24 on/off cycles, a check is made for low battery condition. By substituting other types of sensors, or a switch for the ionization detector, this very-low power device can be used in numerous other safety or security applications.
The A5349CA is supplied in a low-cost, 16-pin dual in-line plastic package. It is rated for continuous operation over the temperature range of 0°C to +50°C.
FEATURES
s Interconnect Up to 125 Detectors s Piezoelectric Horn Driver s Guard Outputs for Detector Input s Low Supply Detection s Power-ON Reset s Internal Timer & Con...