Current Transducer HNC- 200~300P
Current Transducer HNC- 200 .. 300P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic i...
Description
Current Transducer HNC- 200 .. 300P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 200 .. 300 A
Electrical data
Primary nominal DC current Primary current measuring range Type
IPN (A)
200 300
IP (A)
0 .. ± 400 0 .. ± 650 HNC - 200P HNC - 300P HNC - 200P HNC - 300P
RM ISN KN VC IC Vd
Measuing resistance Second nominal current Turns ratio
20 .. 60 100 1 : 2000
20 .. 35 100 1 : 3000
Ω mA V mA kV
Features
Hall effect measuring principle Galvanic isolation between primary Isolation voltage 2500 V Low power consumption
and secondary circuit
Supply voltage (± 5 %) ± 15 Current consumpution 15 + ISN R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 2.5
Accuracy-Dynamic performance data
Advantages
< ± 1 % of IPN < 0.25 % of IPN ± 0.5 mA ± 0.3 mA ± 0.005mA/K°C <1 µs ± 0.04 %/°C
ε
X
L
IO IHC IOT tr TCε G
Accuracy @ T A = 25°C Linearity (0 .. ± IPN ) Electrical offset current @IP = 0, @T A = 25°C Hysteresis offset current @ IP = 0, after an excursion of IPN 0°C .. +70°C Thermal drift of IO Response time @ 90% of IP Thermal drift of the gain (% of reading)
Easy mounting Small size and space saving Only one design for wide current High immunity to external interference
ratings range
Applications
DC motor drives Switched Mode Power Supplies
General data
TA TS RS m Ambient operating temperature Ambient storage ...