Part HLMP-DJ17
Description T-13/4 (5 mm) Precision Optical Performance AlInGaP LED Lamps
Feature HLMP-DJ17; T-13/4 (5 mm) Precision Optical Performance AlInGaP LED Lamps Technical Data SunPower Series HLMP-D.
Manufacture Agilent(Hewlett-Packard)
Datasheet
Download HLMP-DJ17 Datasheet





Agilent(Hewlett-Packard) HLMP-DJ17
T-13/4 (5 mm) Precision Optical
Performance AlInGaP LED
Lamps
Technical Data
SunPower Series
HLMP-DLXX HLMP-GHXX
HLMP-DJXX HLMP-GGXX
HLMP-DHXX HLMP-ULXX
HLMP-DGXX HLMP-UJXX
HLMP-GLXX HLMP-UHXX
HLMP-GJXX HLMP-UGXX
Features
• Well Defined Spatial
Radiation Patterns
• Viewing Angles: 6°, 15°,
23°, 30°
• High Luminous Output
• Colors:
590 nm Amber
605 nm Orange
615 nm Reddish-Orange
626 nm Red
• High Operating
Temperature:
TJ LED = +130°C
• Superior Resistance to
Moisture
• Four Package Options:
With or Without Flange Base;
With or Without Lead Stand-
Offs
Benefits
• Viewing Angles Match
Traffic Management Sign
Requirements
• Colors Meet Automotive and
Pedestrian Signal
Specifications
• Superior Performance in
Outdoor Environments
• Suitable for Autoinsertion
onto PC Boards
Applications
• Traffic Management:
Traffic Signals
Pedestrian Signals
Work Zone Warning Lights
Variable Message Signs
• Commercial Outdoor
Advertising:
Signs
Marquees
• Automotive:
Exterior and Interior Lights
Description
These Precision Optical Perform-
ance AlInGaP LEDs provide
superior light output for excellent
readability in sunlight and are
extremely reliable. AlInGaP LED
technology provides extremely
stable light output over long
periods of time. Precision Optical
Performance lamps utilize the
aluminum indium gallium phos-
phide (AlInGaP) technology.
These LED lamps are untinted,
nondiffused, T-13/4 packages
incorporating second generation
optics producing well defined
spatial radiation patterns at
specific viewing cone angles.
These lamps are made with an
advanced optical grade epoxy,
offering superior high tempera-
ture and high moisture resistance
performance in outdoor signal
and sign applications. The high
maximum LED junction tempera-
ture limit of +130°C enables high
temperature operation in bright
sunlight conditions. The package
epoxy contains both uv-a and
uv-b inhibitors to reduce the
effects of long term exposure to
direct sunlight.
These lamps are available in four
package options to give the
designer flexibility with device
mounting.



Agilent(Hewlett-Packard) HLMP-DJ17
Device Selection Guide
Part
Number
HLMP-
DL08[5]
GL08[5]
DL10[5]
GL10[5]
UL06[5]
UL07[5]
DJ08[5]
GJ08[5]
DJ10[5]
GJ10[5]
UJ06[5]
UJ07[5]
DH08[5]
GH08[5]
DH10[5]
GH10[5]
UH06[5]
UH07[5]
DG08[5]
GG08[5]
DG10[5]
GG10[5]
UG06[5]
UG07[5]
DL15
GL15
DL17
GL17
UL13
UL14
DJ15
GJ15
DJ17
GJ17
Typical
Viewing Angle,
2θ1/2 (Deg.)[4]
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
15
15
15
15
15
15
15
15
15
15
Color,
Dominant
Wavelength,
λd (nm),[3] Typ.
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red, 626
Red, 626
Red, 626
Red, 626
Red, 626
Red, 626
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Luminous Intensity,
Iv (mcd),[1,2]
@ 20 mA
Min.
Typ.
4000
9300
4000
9300
4000
9300
4000
9300
1600
4000
1600
4000
4200
9500
4200
9500
4200
9500
4200
9500
2000
4500
2000
4500
2900
8000
2900
8000
2900
8000
2900
8000
1400
3500
1400
3500
2900
6500
2900
6500
2900
6500
2900
6500
1000
3000
1000
3000
1600
3100
1600
3100
1600
3100
1600
3100
700 1600
700 1600
1400
3400
1400
3400
1400
3400
1400
3400
Leads with
Stand-Offs
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
Flanged
Base
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Package
Drawing
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.



Agilent(Hewlett-Packard) HLMP-DJ17
Device Selection Guide, continued
Part
Number
HLMP-
UJ13
UJ14
DH15
GH15
DH17
GH17
UH13
UH14
DG15
GG15
DG17
GG17
UG13
UG14
DL24
GL24
DL26
GL26
UL22
UL23
DJ24
GJ24
DJ26
GJ26
UJ22
UJ23
DH24
GH24
DH26
GH26
UH22
UH23
Typical
Viewing Angle,
2θ1/2 (Deg.)[4]
15
15
15
15
15
15
15
15
15
15
15
15
15
15
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
Color,
Dominant
Wavelength,
λd (nm),[3] Typ.
Orange, 605
Orange, 605
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red, 626
Red, 626
Red, 626
Red, 626
Red, 626
Red, 626
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Amber, 590
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Orange, 605
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Red-Orange, 615
Luminous Intensity,
Iv (mcd),[1,2]
@ 20 mA
Min.
Typ.
700 1800
700 1800
1400
2500
1400
2500
1400
2500
1400
2500
500 1400
500 1400
1400
2100
1400
2100
1400
2100
1400
2100
500 1000
500 1000
1000
1800
1000
1800
1000
1800
1000
1800
450 1000
450 1000
1000
2000
1000
2000
1000
2000
1000
2000
290 1200
290 1200
700 1500
700 1500
700 1500
700 1500
290 900
290 900
Leads with
Stand-Offs
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
Flanged
Base
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Package
Drawing
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
A
B
C
D
A
C
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)