DC/DC CONVERTERS. DCP0105 Datasheet

DCP0105 CONVERTERS. Datasheet pdf. Equivalent

DCP0105 Datasheet
Recommendation DCP0105 Datasheet
Part DCP0105
Description Miniature 5V Input/ 1W Isolated UNREGULATED DC/DC CONVERTERS
Feature DCP0105; ® DCP 010 5 DCP 010 5 DCP0105 Series Miniature 5V Input, 1W Isolated UNREGULATED DC/DC CONVE.
Manufacture Burr-Brown Corporation
Datasheet
Download DCP0105 Datasheet




Burr-Brown Corporation DCP0105
® DCP0105
DCP0105
DCP0105
Series
Miniature 5V Input, 1W Isolated
UNREGULATED DC/DC CONVERTERS
FEATURES
q STANDARD JEDEC PLASTIC PACKAGE
q MEETS EN55022 CLASS B
q LOW PROFILE: 0.15" (3.8mm)
q SYNCHRONIZABLE
q OUTPUT SHORT CIRCUIT PROTECTION
q THERMAL SHUTDOWN
q STARTS INTO ANY CAPACITIVE LOAD
q FLOATING OUTPUTS
q EFFICIENCY: Up to 75% (at Full Load)
q 1000Vrms ISOLATION
q 400kHz SWITCHING
q 108 MILLION HOURS MTTF
q 5V, ±5V, 12V, ±12V, 15V, ±15V OUTPUTS
q AVAILABLE IN TAPE AND REEL
DESCRIPTION
The DCP0105 family is a series of high efficiency, 5V
input isolated DC/DC converters. In addition to 1W
nominal galvanically isolated output power capability,
the range of DC/DCs are also fully synchronizable.
The devices feature thermal shutdown, and overload
protection is implemented via watchdog circuitry.
Advanced power-on reset techniques give superior
reset performance and the devices will start into any
capacitive load up to full power output.
The DCP0105 family is implemented in standard-
molded IC packaging, giving outlines suitable for high
volume assembly.
APPLICATIONS
q POINT OF USE POWER CONVERSION
q DIGITAL INTERFACE POWER
q GROUND LOOP ELIMINATION
q DATA ACQUISITION
q INDUSTRIAL CONTROL AND
INSTRUMENTATION
q TEST EQUIPMENT
SYNCIN
800kHz
Oscillator
÷2
Reset
Watch-dog/
start-up
Power
Stage
SYNCOUT
VOUT
0V
PSU
Thermal
Shutdown
IBIAS
VS
Power Controller IC
0V
ternational Airport Industrial Park • Mailing Address: PO Box 11400, Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd., Tucson, AZ 85706 • Tel: (520) 746-1111
Twx: 910-952-1111 • Internet: http://www.burr-brown.com/ • Cable: BBRCORP • Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132
©1996 Burr-Brown Corporation
PDS-1336G
Printed in U.S.A. May, 1999



Burr-Brown Corporation DCP0105
SPECIFICATIONS
At TA = +25°C, VS = +5V, unless otherwise specified.
PARAMETER
OUTPUT
Power
Voltage (VNOM)
DCP010505
DCP010505D
DCP010512
DCP010512D
DCP010515
DCP010515D
Voltage vs Temperature
Short-Circuit Duration
Ripple
INPUT
Nominal Voltage (VS)
Voltage Range
Supply Current
Reflected Ripple Current
ISOLATION
Voltage(2)
Continuous Voltage(3)
Insulation Resistance
Input/Output Capacitance
LOAD REGULATION
DCP010505
DCP010505D
DCP010512
DCP010512D
DCP010515
DCP010515D
SWITCHING/SYNCHRONIZATION
Oscillator Frequency (FOSC)
Sync Input Low
Sync Input Current
Reset Time
SYNCOUT Frequency
GENERAL
No Load Current
DCP010505P
DCP010505DP
DCP010512P
DCP010512DP
DCP010515P
DCP010515DP
®
DCP0105
CONDITIONS
DCP0105 SERIES
MIN
TYP
MAX
VS + 4%
100% Full Load
75% Full Load(1)
75% Full Load
75% Full Load
75% Full Load
75% Full Load
75% Full Load
VS ± 10%
CL = O/P Capacitor = 10µF
4.6
±4.6
11.2
±11.2
14.0
±14.0
Indefinite
100% Full Load
CIN = I/P Capacitor = 1µF
50% Full Load
–10
1
0.92
5
±5
12
±12
15
±15
±0.08
20
5
250
20
5.1
±5.1
12.4
±12.4
15.5
±15.5
10
1s Flash Test
1
1
>1
2.5
10% to 100% Load
10% to 75% Load
75% to 100% Load
10% to 100% Load
10% to 75% Load
75% to 100% Load
10% to 100% Load
10% to 25% Load
25% to 75% Load
75% to 100% Load
10% to 100% Load
10% to 25% Load
25% to 75% Load
75% to 100% Load
10% to 100% Load
10% to 25% Load
25% to 75% Load
75% to 100% Load
10% to 100% Load
10% to 25% Load
25% to 75% Load
75% to 100% Load
Switching Frequency = FOSC/2
VSYNC = +2V
0
25 31
17
–8
25 32
19
–8
17 38
7
12
–7
20 37
7
12
–7
20 42
11
12
–7
16 41
11
12
–7
800
0.8
48
3.8
400
0% Full Load
0% Full Load
0% Full Load
0% Full Load
0% Full Load
0% Full Load
2
38
40
30
33
34
34
UNITS
W
W
V
V
V
V
V
V
%/°C
mVp-p
V
%
mA
mArms
kVrms
kVrms
G
pF
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
kHz
V
µA
µs
kHz
mA
mA
mA
mA
mA
mA



Burr-Brown Corporation DCP0105
SPECIFICATIONS (CONT)
At TA = +25°C, VS = +5V, unless otherwise specified.
PARAMETER
GENERAL (Cont)
Efficiency
DCP010505
DCP010505D
DCP010512
DCP010512D
DCP010515
DCP010515D
MTTF(3)
Weight
THERMAL SHUTDOWN
Internal Controller IC Temperature
Shutdown Current
TEMPERATURE RANGE
Operating
CONDITIONS
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
TA = +85°C
TA = +55°C
TA = +25°C
14-Pin PDIP
DCP0105 SERIES
MIN
TYP
MAX
158,000
3,050,000
108,000,000
115
–40
71
40
66
47
72
38
72
36
73
40
75
38
1.08
3
140
+100
NOTES: (1) 100% load current = 1W/VNOM typical. (2) Rated working voltage = 130Vr ms (IEC950 Convention). (3) Life test data.
UNITS
%
%
%
%
%
%
%
%
%
%
%
%
hrs
hrs
hrs
g
°C
mA
°C
EMC SPECIFICATIONS
Specifications and Related Documents
The DCP010505 was tested to and complied with the limits of the following EMC specifications:
prEN55022 (1992) Conducted RF emission, telecomm lines.
EN55022 (1995)
Limits and methods of measurement of radio interference characteristics of information technology equipment.
ENV50140 (1993) Electromagnetic compatibility. Basic immunity standard. Radiated RF immunity.
ENV50141 (1993) Electromagnetic compatibility. Basic immunity standard. Conducted RF immunity.
EN61000-4-2 (1995) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 2. Electrostatic
discharge.
EN61000-4-4 (1995) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 4. Electrical fast
transient bursts.
EN61000-4-8 (1994) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 8. Power frequency
magnetic field immunity.
List of Tests
The following is a list of tests which were required for compliance with the above specifications:
Conducted Emission Test
150kHz to 30MHz, power and output lines, Class B limits applying. DC/DC loads of
0%, 8%, and 120% applying.
Radiated Emission Test
30MHz to 1000MHz, Class B limits applying. DC/DC loads of 0%, 8%, and 120%
applying.
Radiated Immunity Test, Electric Field
80MHz to 1000MHz, 10V/m, 1kHz 80% AM.
Radiated Immunity Test, Electric Field
900MHz, 10V/m, 200Hz 100% PM.
Electrostatic Discharge Test
4kV, HCP/VCP indirect discharge only.
Electrical Fast Transient Tests
2kV power lines, 2kV signal lines.
Conducted RF Immunity Tests
150kHz to 80MHz, power and output lines, 10Vrms, 1kHz 80% AM.
Radiated Immunity Test, Magnetic Field 50Hz, 30A/m
®
3 DCP0105







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)