Document
Low-torque Basic Switch
Highly Reliable Rotary-action Switch for Low Torque Operation
0.5 A rated model (D2MC-01j) employs crossbar alloy #1 contacts which exhibit unsurpassed contact reliability in very small load ranges. High-capacity 5 A Model (D2MC-5j) employs silver contacts. Long life (10,000,000 mechanical operations min.) through use of a movable coil spring.
D2MC
Ordering Information
Direction of actuation Clockwise OF 5.1 g S cm max. 7.6 g S cm max. 10.2 g S cm max. Counterclockwise 5.1 g S cm max. 7.6 g S cm max. 10.2 g S cm max. Note: D2MC-5E D2MC-5F D2MC-5H D2MC-5EL D2MC-5FL D2MC-5HL 5A D2MC-01E D2MC-01F D2MC-01H D2MC-01EL D2MC-01FL D2MC-01HL 0.5 A
All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model name of the actuator lever. See Accessories.
Specifications
Ratings
Item Electrical ratings Inrush current D2MC-5j 5 A at 125/250 VAC (resistive load) NC: 15 A; NO: 7 A 0.5 A D2MC-01j 0.5 A t 125VAC/30 VDC (resistive load)
Contact Form
COM
NO
NC
138
D2MC Characteristics
Item Operating speed Operating frequency Insulation resistance Contact resistance Dielectric strength 1° to 360°/sec Mechanical: 240 operations/min Electrical: 20 operations/min 100 MΩ min. (at 500 VDC) 20 mΩ max. (initial value) 100 mΩ max. (initial value) Mechanical: 240 operations/min Electrical: 60 operations/min D2MC-5j D2MC-01j
D2MC
600 VAC, 50/60 Hz for 1 min between non-continuous terminals 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Destruction: 1,000 m/s2 (approx. 100G) Malfunction: D2MC-jE: 100 m/s2 (approx. 10G) D2MC-jF: 100 m/s2 (approx. 10G) D2MC-jH: 200 m/s2 (approx. 20G) Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. Operating: –25°C to 80°C (with no icing) Operating: 85% max. Approx. 10.5 g Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (1,000,000 operations at 0.1 A, 125 VAC/30 VDC)
Vibration resistance Shock resistance
Life expectancy
Ambient temperature Ambient humidity Weight Note:
All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model name of the actuator lever. See“Accessories”.
Approved Standards
UL (File No. E41515) CSA (File No. LR21642) D2MC-5j series: 5 A, 125 VAC 5 A, 250 VAC D2MC-01j series: 0.5 A, 125 VAC 0.5 A, 30 VDC
Operating Characteristics
Model OF max. RF min. PT max. OT min. MD min. RT min. TT min. FP D2MC-jE 0.5 mN S m (5.1 gf S cm) 0.05 mN S m (0.6 gf S cm) 21° 17° 3° 5° 38° 15±3° D2MC-jF 0.75 mN S m (7.6 gf S cm) 0.09 mN S m (0.9 gf S cm) D2MC-jH 1.0 mN S m (10.2 gf S cm) 0.13 mN S m (1.3 gf S cm)
139
D2MC
D2MC
Engineering Data
Mechanical Life Expectancy
Without load Operating frequency: 240 operations/minute
Electrical Life Expe.