PolySwitch PTC Devices
Tyco/Electronics
Raychem Circuit Protection 308 Constitution Drive Menlo Park, CA 94025-1164 800-227-4856 FAX 800-227-48...
Description
Tyco/Electronics
Raychem Circuit Protection 308 Constitution Drive Menlo Park, CA 94025-1164 800-227-4856 FAX 800-227-4866
PolySwitch® PTC Devices
Overcurrent Protection Device
PRODUCT: LVR025S
DOCUMENT: SCD 24785 PCN: 543478 REV LETTER: F REV DATE: MARCH 21, 2003 PAGE NO.: 1 OF 2
Specification Status: RELEASED
Electrical Rating at 20ºC Rated Operating Voltage: 240 VAC Rated Interrupt Current: 3.5 ARMS
Max Interrupt Voltage: 265 VAC Insulating Material : Cured, Flame Retardant Epoxy Polymer Meets UL94 V-0 Requirements. Lead Material: 22 AWG Sn Plated Copper Marking:
240 L025
Raychem Logo and Voltage Part Identification Lot Identification (can be on back)
TABLE I. DIMENSIONS:
mm: in*: A B MIN MAX MIN MAX -9.6 -17.4 -(0.38) -(0.69) *Rounded off approximation C MIN 4.3 (0.17) MAX 5.8 (0.23) MIN 7.6 (0.30) D MAX -MIN -E MAX 3.8 (0.15)
TABLE II. PERFORMANCE RATINGS:
IHOLD RATED CURRENT AMPS AT 20oC HOLD 0.25 CURRENT RATINGS TIME TO TRIP RESISTANCE POST-TRIP RESISTANCE STANDARD TRIP OHMS AT 20oC MAX 3.8 NOMINAL TRIPPED POWER DISSIPATION WATTS AT 20oC 1.5
AMPS AT 20oC HOLD 0.25 TRIP 0.56
SECONDS AT 20oC, 1.25A MAX 18.5
OHMS AT 20oC MIN MAX 1.3 2.1
Recognitions: Reference Documents: Precedence: Effectivity: Warning:
UL, CSA, TUV recognized. PS300 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Refer to Page 2 of this document for application limitations.
Tyco/Electro...