DatasheetsPDF.com

FIAM1C13 Dataheets PDF



Part Number FIAM1C13
Manufacturers Vicor Corporation
Logo Vicor Corporation
Description Filter Input Attenuator Module
Datasheet FIAM1C13 DatasheetFIAM1C13 Datasheet (PDF)

PRELIMINARY 45 Features • • • • • • • EMI filtering-Class B Transient protection Low profile mounting options 10 and 20 Ampere versions UL, CSA, EN compliance Mini-size package Inrush current limiting Data Sheet FIAM TM Filter Input Attenuator Module Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The FIAM is a DC front-end module providing transient protection, inrush current limiting and Class B EMI filtering in a Minisize package. The FIAM enables design.

  FIAM1C13   FIAM1C13


Document
PRELIMINARY 45 Features • • • • • • • EMI filtering-Class B Transient protection Low profile mounting options 10 and 20 Ampere versions UL, CSA, EN compliance Mini-size package Inrush current limiting Data Sheet FIAM TM Filter Input Attenuator Module Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The FIAM is a DC front-end module providing transient protection, inrush current limiting and Class B EMI filtering in a Minisize package. The FIAM enables designers using Vicor 2nd Generation, 48Vin DC-DC converters to meet the transient immunity and EMI requirements of Bellcore, FCC, ETSI and European Norms while protecting system hardware from inrush current. The FIAM accepts an input voltage of 36-76Vdc, is available in 10 or 20A versions and provides reverse polarity protection and remote on/off. FIAM is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications. Absolute Maximum Rating Parameter +In to –In +In to –In +Out to –Out Mounting torque Pin Soldering temperature Pin Soldering temperature Storage temperature C–, T–Grade Operating temperature C–Grade Operating temperature T–Grade Rating 80 100 75 5(0.57) 500 (260) 750 (390) -40 to +125 -20 to +100 -40 to +100 Unit Vdc V Vdc in-lbs °F(°C) °F(°C) °C °C °C Notes Continuous 100ms Continuous 6 each, #4-40 or M3 <5 sec; wave solder <7 sec; hand solder Baseplate Baseplate Specifications (typical at TBP = 25C, nominal line, 75% load, unless otherwise specified) Compatible Products • 2nd Generation 48V Input DC-DC converters Parameter Min Input voltage 36Vdc Output current FIAM1xxx FIAM2xxx Inrush limiting Transient immunity Bellcore TR-NWT-000499 ETS 300 386-1 Class 2 EMI Bellcore GR-001089-Core EN 55022 FCC Part 15 Dielectric withstand Efficiency Reverse polarity protection ON/OFF control Enable (ON) Disable (OFF) External capacitance FIAM1xxx FIAM2xxx Safety approvals Weight Warranty 96 Typ 48Vdc Max 76Vdc 10A 20A .014A/µF 200V 200V 250V Remarks Continuous 1µsec duration 5.0µsec rise time, 50µsec duration surge 1-100nsec burst When used with Vicor 2nd Generation 48Vin DC-DC converters Part Number Format FIAM Product 1 C 1 Pin Style 1 = Short 2 = Long 1 Type 1 = 10A 2 = 20A Product Grade C = –20 to +100 T = –40 to +100 Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole Issue 2 Level B Level B 1,500Vrms 2,121Vdc 97.5 Input/Output to Base Input/Output to Base Internal voltage drop is 1.4 max. @ 20A, 100°C baseplate No damage to module, external fuse required 1.0Vdc 5.0Vdc Referenced to –Vout. 100kΩ internal pull-up resistor See illustration on page 2. 100V 100V Thermal Resistance Parameter Typ Baseplate to sink; flat, greased surface 0.16°C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt Baseplate to ambient 7.9°C/Watt Baseplate to sink; 1000 LFM 2.2°C/Watt 0.0Vdc 3.5Vdc 10µF 150µF 100µF 330µF UL 1950, CSA 22.2-950, EN 60950 3.1 (88) 4 (113) ounces (grams) 2 years Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FIAM, Filter Input Attenuator Module Rev. 1.1 Page 1 of 4 Set your site on VICOR at www.vicorpower.com PRELIMINARY Conducted Noise Figure 1—FIAM and Model V48A12C500A DC-DC converter. Figure 2—FIAM and Model V48B24C250A DC-DC converter. Inrush Limiting Transient Immunity Tek Stop: Single Seq. 5.00MS/s [ T Ch1 Zoom: ] Tek Run: 10.0MS/s 1.0X Vert 0.005X Horz @ 200.0V INPUT CURRENT INPUT VOLTAGE Ch1=Vdc in Ch2=Vdc out Ch3=Idc in @0.2A/mV © INPUT TRANSIENT Ch1=Input Ch2=Output 4© © OUTPUT VOLTAGE 2© 2© Ch1 10.0 V Ch2 Ch4 10.0 V M2.00ms 10.0mVΩ Ch1 31.8 V OUTPUT VOLTAGE 48V offset Ch1 25.0V Ch2 25.0V M5.00µs Ch4 8.2A Figure 3—Inrush Limiting: Inrush current with 330µF external capacitance. Figure 4—Transient Immunity: FIAM output response to an input transient. Transient and Surge Protection Note: The FIAM is shown in the on state. To disable, open the connection between ON/OFF and –Out. –IN –IN EMI GND –OUT ON OFF –IN PR –OUT TRANSORB P/N 20461-120 +IN FIAM NC +IN NC NC +OUT PC +IN 2nd Generation 48Vdc Input DC-DC Converters –S SC +S +OUT Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FIAM, Filter Input Attenuator Module Rev. 1.1 Page 2 of 4 Set your site on VICOR at www.vicorpower.com PRELIMINARY Mechanical Diagram No. 1 2 3 4 5 6 7 8 9 Converter Pins Function Label +In + No NC Connection Ground EMI/GND – In – – Out – ON/OFF ON/OFF No NC Connection No NC Connection +Out + 0.50 ±0.02 12,7 ±0,5 0.23 (REF) 5,8 0.300 ±0.015 7,62 ±0,38 2.20 55,9 1.74 44,2 style 2 & 3 baseplates only (4X)*** 0.12* 0.20** 3,1 5,1 0.01 0.49 12,4 2.000 50,80 0.10 2,5 0.10 X 45˚ 2,5 CHAMFER 0.300 ±0.015 7,62 ±0,38 1 (ALL MARKINGS THIS SURFACE) 2 3 4 1.900 48,26 0.35 (2X) 8,8 ALUMINUM BASEPLATE 2.28 1.30 57,9 33,0 0.65 16,5 FULL R (6X) 0.130 3,30 (6X) 9 8 7 6 5 Use a 4-40 Screw (6X) Torque to: 5 i.


FIAM1C12 FIAM1C13 FIAM1C21


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)