Document
IMS 7 Series
7 Watt DC-DC Converters
Wide input voltage ranges up to 75 V DC 1 or 2 outputs up to 48 V DC 1500 V DC I/O electric strength test voltage
• Magnetic feedback for single output models • Short circuit protection • Industry standard 2" x 1" case with 10.5 mm profile
Selection chart
Output 1 Output 2 Input voltage Type Uo nom Io nom Uo nom Io nom Ui [V DC] [mA] [V DC] [mA] [V DC] 3.3 1200 14...36 24 IMS 7-03-9 3.3 1200 36...75 48 IMS 7-03-9 5.1 1200 14...36 24 IMS 7-05-9 5.1 1200 36...75 48 IMS 7-05-9 12 600 14…36 24 IMS 7-12-9C 12 600 36…75 48 IMS 7-12-9C 15 480 14…36 24 IMS 7-15-9C 15 480 36…75 48 IMS 7-15-9C 5 700 5 700 14...36 24 IMS 7-05-05-9 5 700 5 700 36...75 48 IMS 7-05-05-9 12 300 12 300 14...36 24 IMS 7-12-12-9 12 300 12 300 36...75 48 IMS 7-12-12-9 15 240 15 240 14...36 24 IMS 7-15-15-9 15 240 15 240 36...75 48 IMS 7-15-15-9 24 150 24 150 14...36 24 IMS 7-24-24-9 24 150 24 150 36...75 48 IMS 7-24-24-9 1 For minimum order quantities and lead times contact Power-One. 2 Option M, C, L and Z exclude each other. Options 1, 2
M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z
M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z M, C, L, Z
www.power-one.com
Edition 3/04.2001
1
Board Mountable
Input
Input voltage range 24 IMS 7 48 IMS 7
IMS 7 Series
14...36 V DC 36...75 V DC
Output
Output voltage setting accuracy Ui nom , 50% lo nom , single output models ±1% Uo nom Ui nom , 50% lo nom, double output, main/aux. output ±1.5 % Uo nom Minimum load recommended for double output models 10% lo nom Line/load regulation Ui min...Ui max, 50% lo nom , single output models ±1% Uo nom Line regulation Ui nom , 50% lo nom, double output models, main output ±1% Uo nom Load regulation Ui nom , 10...100% lo nom, double output models ± 3% Uo nom tracking output ± 3% Uo nom Output voltage switching noise Ui nom , 0...100% lo nom , peak-peak, total max. 1.5% Uo nom Efficiency Ui nom , lo nom up to 84%
Control and protection
Input protection Overload protection No-load protection Remote shut down Trim input for Uo suppressor diode Ui min...Ui max, any load fully protected, hiccup mode yes TTL-compatible inhibit input disabled with ≥ 2.4 V yes
Safety and EMC
Electric strength test voltage Electromagnetic interference I/O 1500 V DC class B
Environmental
Operating ambient temperature Storage temperature Relative humidity MTBF
Ui nom, lo nom non operational non condensing GB 40 °C, MIL-HDBK-217F, N2
–40...71°C –40...100 °C 93% 1'650'000 h
Options
SMD version SMD version Open frame version C-pinout with pins with PCB lid M L Z C
Accessories
DIN and chassis mounting bracket
www.power-one.com
Edition 3/04.2001
2
IMS 7 Series
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
7 Watt DC-DC Converters
European Projection
IMS 7
S09030
50.8 (2") 3.4 (0.13") 3.81(0.15")
0.8 × 1.2 (0.03 x 0.05") Pins ∅ 1.6 (0.06) PCB holes
3 x 5.08 (0.2")
3.81(0.15")
4 3.81(0.15")
10
4.6 (0.18") Measuring point of case.