Current Transducer HX 05~10-NP
Current Transducer HX 05...10-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isol...
Description
Current Transducer HX 05...10-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN =
5 .. 10 A
Electrical data
Primary nominal r.m.s. current IPN (A) Series Parallel Primary current measuring range IP (A) Series ± 15 ± 30 Parallel Primary Conductor Diameter x Turns (mm) Type
Features
Galvanic isolation between primary
and secondary circuit
± 5 ± 10 VOUT ROUT RL VC IC Vd
± 10 ± 20
± 30 ± 60
0.7d x (6T+6T) 1.0d x (3T+3T)
HX 05-NP HX 10-NP V Ω kΩ V mA kV kV
Ve
Output voltage @ ± IPN, RL = 10 k Ω, TA = 25°C ±4 Output impedance < 50 Load resistance ≥ 10 Supply voltage (± 5 %)1) ± 15 Current consumption < ± 20 R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn Primary to secondary >3 Primary 1 to primary 2 >1 R.m.s. voltage for partial discharge extinction at 10pC ≥1 Impulse withstand voltage, 1.2/50µs ≥6
Hall effect measuring principle 2 isolated primary windings Isolation voltage 3000V Low power consumption Extended measuring range(3x IPN) Power supply from ±12V to ±15V Material according to UL94-V0
Advantages
kV kV
Low insection losses Easy to mount with automatic Small size and space saving High immunity to external
interference. handling system
Accuracy-Dynamic performance data
X
ε
L
VOE VOH VOT TCε G tr f
Accuracy @ IPN, TA = 25°C (without offset) Linearity (0 .. ± IPN) Electrical offset voltage, TA...
Similar Datasheet