Current Transducer
Current Transducer HX 03 ... 50-P
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separatio...
Description
Current Transducer HX 03 ... 50-P
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
IP N = 3 ... 50 A
Electrical data
Primary nominal Primary current, Primary conductor
Type RMS current measuring range diameter × turns
HX 03-P
IP N (A) 3
IP M (A) (mm) ±9 0.6 d × 20 T
HX 05-P
5 ±15 0.8 d × 12 T
HX 10-P
10 ±30 1.1 d × 6 T
HX 15-P
15 ±45 1.4 d × 4 T
HX 20-P
20 ±60 1.6 d × 3 T
HX 25-P
25 ±75 1.6 d × 2 T
HX 50-P
50 ±150 1.2 × 6.3 × 1 T
Uout Output voltage (Analog) @ ±IPN, RL = 10 kΩ, TA = 25 °C ±4
RL Load resistance
≥ 10
Rout Output internal resistance
< 50
UC Supply voltage (±5 %) 1)
±15
IC Current consumption
< ±15
V kΩ Ω
V mA
Accuracy - Dynamic performance data
ε Error @ IP N, TA = 25 °C (excluding offset)
εL Linearity error (0 ... ±IP N)
UO E Electrical offset voltage @ TA = 25 °C
UO H Hysteresis offset voltage @ IP = 0,
after an excursion of 1 × IP N
TCUO E Temperature coefficient of UO E
TCUout Temperature coefficient of Uout (% of reading)
tD 90 Delay time to 90 % of IP N
BW Frequency bandwidth (−3 dB) 2)
< ±1 < ±1 < ±40
% of IP N % of IP N
mV
±15 (typ) < ±1.5 ±0.1 ≤ 3 50
mV mV/K
%/K µs
kHz
General data
TA TS m
Ambient operating temperature Ambient storage temperature Mass Standard
−25 ... +85 °C −...