DatasheetsPDF.com

TSOP1230CB1 Dataheets PDF



Part Number TSOP1230CB1
Manufacturers Vishay Telefunken
Logo Vishay Telefunken
Description Photo Modules for PCM Remote Control Systems
Datasheet TSOP1230CB1 DatasheetTSOP1230CB1 Datasheet (PDF)

TSOP11..CB1 Vishay Telefunken Photo Modules for PCM Remote Control Systems Available types for different carrier frequencies Type TSOP1130CB1 TSOP1136CB1 TSOP1138CB1 TSOP1156CB1 fo 30 kHz 36 kHz 38 kHz 56 kHz Type TSOP1133CB1 TSOP1137CB1 TSOP1140CB1 fo 33 kHz 36.7 kHz 40 kHz Description The TSOP11..CB1 – series are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter. The demodulated outpu.

  TSOP1230CB1   TSOP1230CB1


Document
TSOP11..CB1 Vishay Telefunken Photo Modules for PCM Remote Control Systems Available types for different carrier frequencies Type TSOP1130CB1 TSOP1136CB1 TSOP1138CB1 TSOP1156CB1 fo 30 kHz 36 kHz 38 kHz 56 kHz Type TSOP1133CB1 TSOP1137CB1 TSOP1140CB1 fo 33 kHz 36.7 kHz 40 kHz Description The TSOP11..CB1 – series are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter. The demodulated output signal can directly be decoded by a microprocessor. The main benefit is the operation with short burst transmission codes (e.g. RECS 80) and high data rates. 13 641 Features D Photo detector and preamplifier in one package D Internal filter for PCM frequency D Improved shielding against electrical field disturbance Special Features D Enhanced data rate of 3500 bit/s D Operation with short bursts possible (≥6 cycles/burst) D D D D TTL and CMOS compatibility Output active low Low power consumption High immunity against ambient light Block Diagram 2 Input Control Circuit 80 kΩ 3 PIN AGC Band Pass Demodulator 1 GND 94 8136 VS OUT Document Number 82148 Rev. 3, 29-Mar-01 www.vishay.com 1 (8) TSOP11..CB1 Vishay Telefunken Absolute Maximum Ratings Tamb = 25_C Parameter Supply Voltage Supply Current Output Voltage Output Current Junction Temperature Storage Temperature Range Operating Temperature Range Power Consumption Soldering Temperature Test Conditions (Pin 2) (Pin 2) (Pin 3) (Pin 3) Symbol VS IS VO IO Tj Tstg Tamb Ptot Tsd Value –0.3...6.0 5 –0.3...6.0 5 100 –25...+85 –25...+85 50 260 Unit V mA V mA °C °C °C mW °C (Tamb 85 °C) t 10 s, 1 mm from case x x Basic Characteristics Tamb = 25_C Parameter Supply Current (Pin 2) Supply Voltage (Pin 2) Transmission Distance Output Voltage Low (Pin 3) Irradiance (30 – 40 kHz) Irradiance (56 kHz) Irradiance Directivity Ev = 0, test signal see fig.8, IR diode TSAL6200, IF = 0.4 A IOSL = 0.5 mA,Ee = 0.7 mW/m2, f = fo, test signal see fig.7 Test signal see fig.7 Test signal see fig.8 Test signal see fig.7 Test signal see fig.8 Test signal see fig.7 Angle of half transmission distance Test Conditions VS = 5 V, Ev = 0 VS = 5 V, Ev = 40 klx, sunlight Symbol ISD ISH VS d VOSL Ee min i Ee min Ee max ϕ1/2 30 ±45 0.4 0.35 0.45 0.40 Min 0.4 4.5 35 250 0.6 0.5 0.7 0.6 Typ 0.6 1 Max 1.5 5.5 Unit mA mA V m mV mW/m2 mW/m2 W/m2 deg Application Circuit 100 W *) 2 TSOP11.. TSAL62.. 3 **) 1 12755 +5V >10 kW optional 4.7 mF *) mC GND *) recommended to suppress power supply disturbances **) The output voltage should not be hold continuously at a voltage below 3.3V by the external circuit. www.vishay.com 2 (8) Document Number 82148 Rev. 3, 29-Mar-01 TSOP11..CB1 Vishay Telefunken Suitable Data Format The circuit of the TSOP11..CB1 is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances. The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle. The data signal should fullfill the following condition: • Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz). • Burst length should be 6 cycles/burst or longer. • After each burst which is between 6 cycles and 70 cycles a gap time of at least 10 cycles is neccessary. • For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should have at least same length as the burst. • Up to 2200 short bursts per second can be received continuously. Some examples for suitable data format are: NEC Code, Toshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, RCMM Code, R–2000 Code, RECS–80 Code. When a disturbance signal is applied to the TSOP11..CB1 it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure. Some examples for such disturbance signals which are suppressed by the TSOP11..CB1 are: • DC light (e.g. from tungsten bulb or sunlight) • Continuous signal at 38kHz or at any other frequency • Signals from fluorescent lamps with electronic ballast (an example of the signal modulation is in the figure below). 0 5 10 time [ms] 15 20 IR Signal from Fluorescent Lamp with low Modulation Document Number 82148 Rev. 3, 29-Mar-01 www.vishay.com 3 (8) TSOP11..CB1 Vishay Telefunken Typical Characteristics (Tamb = 25_C unless otherwise specified) Ee min – Threshold Irradiance ( mW/m2 ) 1.0 /eE – Rel. Responsitivity 0.8 2.0 f ( E ) = f0 1.6 1.2 0.8 0.4 0.0 0.7 94 9102 0.6 0.4 0.2 0.0 0.8 0.9 1.0 1.1 1.2 1.3 f / f0 – Relative Frequency Df ( 3 dB ) = f0 / 7 f = f0 "5% eE min 0.0 94 8147 0.4 0.8 1.2 1.6 2.0 E – Field Strength of Disturbance ( kV / m ) Figure 1. Frequency Dependence of Responsivity 0.30 tpo – Output Pulse Length (ms) 0.25 0.20 Input burst duration 0.15.


TSOP1230 TSOP1230CB1 TSOP1230GL1


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)