TRISIL
®
TPA SERIES
TRISIL™
FEATURES BIDIRECTIONAL CROWBAR PROTECTION. VOLTAGE RANGE: FROM 62 V TO 270 V. HOLDING CURRENT : I...
Description
®
TPA SERIES
TRISIL™
FEATURES BIDIRECTIONAL CROWBAR PROTECTION. VOLTAGE RANGE: FROM 62 V TO 270 V. HOLDING CURRENT : IH = 150mA min. REPETITIVE PEAK PULSE CURRENT : IPP = 50 A, 10/1000 µs.
F126 DESCRIPTION The TPA series are TRISIL devices especially designed for protecting sensitive telecommunication equipment against lightning and transient voltages induced by AC power lines. They are available in the F126 axial package. TRISIL devices provide bidirectional protection by crowbar action. Their characteristic response to transient overvoltages makes them particularly suited to protect voltage sensitive telecommunication equipment. COMPLIES WITH THE FOLLOWING STANDARDS: (CCITT) ITU-K20 (CCITT) ITU-K17 VDE0433 VDE0878 IEC-1000-4-5 FCC Part 68, lightning surge type A FCC Part 68, lightning surge type B BELLCORE TR-NWT-001089 First level BELLCORE TR-NWT-001089 Second level CNET l31-24
October 1998 - Ed: 9A
SCHEMATIC DIAGRAM
Peak Surge Voltage (V) 1000 1500 2000 2000 level 3 level 4 1500 800 1000 2500 1000 5000 1000
Voltage Waveform (µs) 10/700 10/700 10/700 1.2/50 10/700 1.2/50 10/160 10/560 9/720 2/10 10/1000 2/10 0.5/700
Current Waveform (µs) 5/310 5/310 5/310 1/20 5/310 8/20 10/160 10/560 5/320 2/10 10/1000 2/10 0.8/310
Admissible Ipp (A) 25 38 50 50 50 100 75 55 25 150 50 150 25
Necessary Resistor (Ω) 12.5 6.5 11.5 10 11.5 1/5
TPA SERIES
ABSOLUTE MAXIMUM RATINGS (Tamb = 25°C) Symbol P IPP ITSM I t dV/dt Tstg Tj TL
2
Parameter Power dissipation on infinite heatsink ...