TRIPOLAR OVERVOLTAGE PROTECTION FOR TELECOM LINE
®
THBTxxx11D
TRIPOLAR OVERVOLTAGE PROTECTION FOR TELECOM LINE
Application Specific Discretes A.S.D.™
FEATURES BIDIRECT...
Description
®
THBTxxx11D
TRIPOLAR OVERVOLTAGE PROTECTION FOR TELECOM LINE
Application Specific Discretes A.S.D.™
FEATURES BIDIRECTIONAL CROWBAR PROTECTION BETWEEN TIP AND GND, RING AND GND AND BETWEEN TIP AND RING. PEAK PULSE CURRENT : IPP = 30A for 10/1000µs surge. HOLDING CURRENT : IH = 150mA. AVAILABLEIN SO8 PACKAGES. LOW DYNAMIC BREAKOVER VOLTAGE. DESCRIPTION Dedicated to telecommunication equipment protection, these devices provide a triple bidirectional protection function. They ensure the same protection capability with the same breakdown voltage both in longitudinal mode and transversal mode. A particular attention has been given to the internal wire bonding. The ”4-point” configuration ensures a reliable protection, eliminating overvoltages introduced by the parasitic inductances of the wiring (Ldi/dt), especially for very fast transient overvoltages. Dynamic characteristics have been defined for several types of surges, in order to meet the SLIC maximum ratings. COMPLIESWITHTHE FOLLOWINGSTANDARDS : CCITT K20 : VDE 0433 : VDE 0878 : CNET : FCC part 68 : BELLCORE TR-NWT-001089 :
(*) With series resistors or PTC.
SO8
SCHEMATIC DIAGRAM
TIP 1 GND 2 GND 3 RING 4
8 TIP 7 GND 6 GND 5 RING
10/700µs 5/310µs 10/700µs 5/310µs 1.2/50µs 1/20µs 0.5/700µs 0.2/310µs 2/10µs 2/10µs 2/10µs 2/10µs
1.5kV 20A (*) 2kV 20A (*) 1.5kV 20A (*) 1.5kV 20A (*) 2.5kV 40A (*) 2.5kV 40A (*)
TM: ASD is trademarks of SGS-THOMSON Microelectronics.
September 1998 - Ed: 5A
1/9
THBTxxx11D
ABSOLUTE MAXIMUM ...