DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS
Copyright © 1999, Power Innovations Limited, UK
TISP61089AS DUAL FORWARD-CONDUCTING P-GATE THYRISTORS
PROGRAMMABLE OVER...
Description
Copyright © 1999, Power Innovations Limited, UK
TISP61089AS DUAL FORWARD-CONDUCTING P-GATE THYRISTORS
PROGRAMMABLE OVERVOLTAGE PROTECTORS
OCTOBER 1999
RINGING SLIC OVERVOLTAGE PROTECTION FOR LSSGR ‘1089
q Dual Voltage-Programmable Protectors — High Voltage Rating ........................-120 V — Wide Programming Range..... 0 to -100 V — Low Gate Triggering Current .......< 5 mA — High Holding Current ................> 150 mA
q Increased Gound Pin Clearance Version of TISP61089AD
— Ground Lead Creepage ................ > 3 mm — Small Outline Surface Mount Package
q Rated for LSSGR ‘1089 Conditions
D PACKAGE (TOP VIEW)
(Tip) K1
1
8 NC
(Gate) G 2 7 A (Ground)
NC 3
6 A (Ground)
(Ring) K2
4
5 NC
MD6XBA
NC - No internal connection Terminal typical application names shown in
parenthesis
WAVE SHAPE
2/10 µs 10/1000 µs
‘1089 TEST CLAUSE AND TEST #
4.5.8 Second-Level 1 4.5.7 First-Level 3
ITSP A 120 30
device symbol
K1
60 Hz POWER FAULT TIME
100 ms 1s 5s
300 s 900 s
‘1089 TEST CLAUSE AND TEST #
4.5.13 Second-Level 2 4.5.13 Second-Level 2 4.5.13 Second-Level 2 4.5.13 Second-Level 1 4.5.13 Second-Level 1
ITSM A 11 4.8 2.7
0.95 0.92
q 2/10 Protection Voltage Specified
ELEMENT
Diode Crowbar VGG = -48 V
FIRST-LEVEL V @ 56 A 6
-57
SECOND-LEVEL V @ 100 A 8
-60
q Rated for ITU-T K20 & K21 impulses
WAVE SHAPE
VOLTAGE
CURRENT
10/700 µs
5/320
ITSP A 40
A
G1,G2 A
K2
Terminals K1, K2 and A correspond to the alternative
line designators of T, R and G or A, B and C....