INTERFACE ADAPTOR. PA9605AP Datasheet

PA9605AP ADAPTOR. Datasheet pdf. Equivalent

PA9605AP Datasheet
Recommendation PA9605AP Datasheet
Part PA9605AP
Description THREE PHASE POWER/ENERGY METERING INTERFACE ADAPTOR
Feature PA9605AP; sames FEATURES n SA9605APA APPLICATION NOTE PA9605AP THREE PHASE POWER/ENERGY METERING INTERFACE A.
Manufacture Sames
Datasheet
Download PA9605AP Datasheet




Sames PA9605AP
sames
SA9605APA APPLICATION NOTE
PA9605AP
THREE PHASE POWER/ENERGY
METERING INTERFACE ADAPTOR
FEATURES
n Demonstration of the SA9605APA n
device using a PM9105APE module
n Pulse rate selectable via jumper leads
n Energy direction indicator provided
Meets the accuracy requirements for
Class 1 AC Watt hour meters
DESCRIPTION
The PA9605AP interface adaptor converts the SA9605APA (DIP-20) package to a
SA9105XP (DIP-40) footprint. This enables the evaluation of the SA9605APA using the
PM9105AP evaluation module.
It is advised that this Application Note should be read in conjunction with the PM9105AP
Application Note.
7185
PDS038-SA9605-001
Rev. A
1/6
19-03-97



Sames PA9605AP
PA9605AP
BLOCK DIAGRAM
CONNECTION DESCRIPTION
Designation Location Description
PL5 PM9105AP Voltage Supply connected to Phase 1
Voltage Supply connected to Phase 2
Voltage Supply connected to Phase 3
Voltage Supply connected to Neutral Line (Common)
PL6.1
PL6.2
PL6.3
PM9105AP
Power Output: FOUT1
Power Output: FOUT2
Direction Indication: DIR
PL4 PM9105AP 5V DC Supply Voltage
0V DC Supply Voltage
CT1 PM9105AP Phase 1 (Direction indicated on PCB)
CT2 Phase 2 (Direction indicated on PCB)
CT3 Phase 3 (Direction indicated on PCB)
PGM0
PGM1
PA9605AP FOUT2 Frequency select
Refer to Table in part 2
2/6 sames



Sames PA9605AP
PA9605AP
FUNCTIONAL DESCRIPTION
1. Interface Board
The PA9605AP interface adaptor board (see Fig. 1) allows the connection of a
SA9605APA (DIP-20) device to an evaluation board of type PM9105AP. This
Interface Board inserts into the dual-in-line socket of the PM9105AP module in the
same orientation that the SA9105XPA (DIP-40) device is normally inserted.
Figure 1: Connection Diagram
2. Frequency Select Output, FOUT2
Although FOUT1 has a fixed frequency output of 1160Hz for rated conditions, the
table below shows the various frequencies selectable for rated conditions, on
FOUT2.
User Selectable Output Frequency
PGM1
PGM0
FOUT2
Connection Level Connection Level (Hz)
1-2 0 1-2
0 5.11
1-2 0 1-2
1 3.83
2-3 1 2-3
0 2.55
2-3 1 2-3
1 n/a
sames
3/6