Document
MCC
Features
• • • •
omponents 21201 Itasca Street Chatsworth !"# $
% !"#
MBR2520 THRU MBR25100
25 Amp Schottky Barrier Rectifier 20 to 100 Volts
Metal of siliconrectifier, majonty carrier conducton Guard ring for transient protection Low power loss high efficiency High surge capacity, High current capability
Maximum Ratings
• •
Operating Temperature: -55 °C to +150°C Storage Temperature: -55°C to +150°C Device Marking Maximum Recurrent Peak Reverse Voltage 20V 30V 35V 40V 45V 60V 80V 100V Maximum RMS Voltage Maximum DC Blocking Voltage 20V 30V 35V 40V 45V 60V 80V 100V
TO-220AC
B F Q T A U C S
Microsemi Catalog Number
MBR2520 MBR2530 MBR2535 MBR2540 MBR2545 MBR2560 MBR2580 MBR25100
MBR2520 MBR2530 MBR2535 MBR2540 MBR2545 MBR2560 MBR2580 MBR25100
14V 21V 24.5V 28V 31.5 42V 56V 70V
H K L
D
J
R
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element MBR2020-2045 Maximum DC Reverse Current At Rated DC Blocking Voltage IF(AV) 25A TC = 130°C
G
IFSM
150A
8.3ms, half sine
A B C D F G H J K L Q R S T U
MM 15.11 9.65 4.06 0.64 3.61 4.83 2.79 0.46 12.70 1.14 2.54 2.04 1.14 5.97 ---- 15.75 10.29 4.82 0.89 3.73 5.33 3.30 0.64 14.27 1.52 3.04 2.79 1.39 6.48 1.27
VF
MBR2060 MBR2080-20100
.63V .75V .84V
IFM = 25A per element; TA = 25°C*
IR 0.2mA TJ = 25°C
INCHES .595 .620 .380 .405 .160 .190 .025 .035 .142 .147 .190 .210 .110 .130 .018 .025 .500 .562 .045 .060 .100 .120 .080 .110 .045 .055 .235 .255 -----.050
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
www.mccsemi.com
MBR2520 thru MBR25100
Figure 1 Typical Forward Characteristics 100 60 40 20 MBR2520-2545 10 6 4 2 25°C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .3 .4 .5 .6 .7 .8 MBR2580-25100 .2 TJ=25°C µ Amps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 50 75 MBR2560 10 6 4 2 1 .6 .4
MCC
Figure 2 Typical Reverse Characteristics
100 Volts
125 150
175
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 25
Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
Figure 4 Peak Forward Surge Current 150
20 125 15 100 75 Amps 8 25 5 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 °C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 100 130 150 0 1 4 6 8 10 Cycles Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles 20 40 60 80 100 50
10 Amps
2
www.mccsemi.com
.