INTEGRATED FUNCTIONS AND FEATURES
Converter bridge for 3 phase AC-to-DC power conversion. Circuit for dynamic braking of motor regenerative energy. 3-phase IGBT inverter bridge configured by the latest 3rd. generation IGBT and diode technology. Inverter output current capability IO (Note 1): Type Name PS11014 100% load 5.0A (rms) 150% over load 7.5A (rms), 1min
(Note 1) : The inverter output current is assumed to be sinusoidal and the peak current value of each of the above loading cases is defined as : IOP = IO × √ 2
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS:
For inverter side upper-leg IGBTs : Drive circuit, High voltage isolated high-speed level shifting, Short circuit protection (SC). Bootstrap circuit supply scheme (single drive power supply) and Under voltage protection (UV). For inverter side lower-leg IGBTs : Drive circuit, Short circuit protection (SC). Control supply circuit under- & over- voltage protection (OV/UV). System over temperature protection (OT). Fault output signaling circuit (FO) and Current limit warning signal output (CL). For Brake circuit IGBT : Drive circuit Warning and Fault signaling : FO1 : Short circuit protection for lower-leg IGBTs and Input interlocking against spurious arm shoo...