dual gain-stage. SA5200 Datasheet

SA5200 gain-stage. Datasheet pdf. Equivalent

SA5200 Datasheet
Recommendation SA5200 Datasheet
Part SA5200
Description RF dual gain-stage
Feature SA5200; INTEGRATED CIRCUITS IN2 4 GND2 3 OUT2 2 VCC 1 AMP2 AMP1 5 ENABLE 6 IN1 7 GND1 8 OUT1 SA52.
Manufacture Philips
Datasheet
Download SA5200 Datasheet





Philips SA5200
INTEGRATED CIRCUITS
IN2 GND2
43
AMP2
5
ENABLE
6
IN1
SA5200
RF dual gain-stage
Product Specification
Replaces data of Oct 10 1991
IC17 Data Handbook
Philips Semiconductors
OUT2
2
AMP1
7
GND1
VCC
1
8
OUT1
1997 Nov 07



Philips SA5200
Philips Semiconductors
RF dual gain-stage
Product specification
SA5200
DESCRIPTION
The SA5200 is a dual amplifier with DC to 1200MHz response. Low
noise (NF = 3.6dB) makes this part ideal for RF front-ends, and a
simple power-down mode saves current for battery operated
equipment. Inputs and outputs are matched to 50.
The enable pin allows the designer the ability to turn the amplifiers
on or off, allowing the part to act as an amplifier as well as an
attenuator. This is very useful for front-end buffering in receiver
applications.
FEATURES
Dual amplifiers
DC - 1200MHz operation
Low DC power consumption (4.2mA per amplifier @ VCC = 5V)
Power-Down Mode (ICC = 95µA typical)
3.6dB noise figure at 900MHz
Unconditionally stable
Fully ESD protected
Low cost
ORDERING INFORMATION
DESCRIPTION
8-Pin Plastic Small Outline (Surface–mount)
BLOCK DIAGRAM
IN2 4
GND2 3
PIN CONFIGURATION
D Package
VC 1
OUTC2 2
GND2 3
IN2 4
8 OUT1
7 GND1
6 IN1
5 ENABLE
Figure 1. Pin Configuration
Supply voltage 4-9V
Gain S21 = 7dB at f = 1GHz
Input and output match S11, S22 typically <–14dB
APPLICATIONS
Cellular radios
RF IF strips
Portable equipment
SR00166
TEMPERATURE RANGE
–40-+85°C
ORDER CODE
SA5200D
DWG #
SOT96-1
OUT2 2
VCC 1
AMP2
AMP1
5
ENABLE
6
IN1
7
GND1
Figure 2. Block Diagram
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC Supply voltage
Operating ambient temperature range
TA SA Grade
Operating junction temperature
TJ SA Grade
8
OUT1
RATING
4.0 to 9.0
-40 to +85
-40 to +105
SR00167
UNITS
V
°C
°C
1997 Nov 07
5–2 853-1578 18662



Philips SA5200
Philips Semiconductors
RF dual gain-stage
Product specification
SA5200
ABSOLUTE MAXIMUM RATINGS
SYMBOL
PARAMETER
VCC Supply voltage1
PD
Power dissipation, TA = 25°C (still air)2
8-Pin Plastic SO
RATING
-0.5 to +9
780
TJMAX
PMAX
TSTG
Maximum operating junction temperature
Maximum power input/output
Storage temperature range
150
+20
–65 to +150
NOTE:
1. Transients exceeding 10.5V on VCC pin may damage product.
2. Maximum dissipation is determined by the operating ambient temperature and the thermal resistance, θJA:
8-Pin SO:
θJA = 158°C/W
UNITS
V
mW
°C
dBm
°C
DC ELECTRICAL CHARACTERISTICS
VCC = +5V, TA = 25°C; unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS
VCC Supply voltage
VCC = 5V, ENABLE = High
ICC Total supply current
VCC = 5V, ENABLE = Low
VCC = 9V, ENABLE = High
VT TTL/CMOS logic threshold voltage1
VCC = 9V, ENABLE = Low
VIH Logic 1 level
Power-up mode
VIL Logic 0 level
Power-down mode
IIL Enable input current
Enable = 0.4V
IIH Enable input current
Enable = 2.4V
VIDC,ODC Input and output DC levels
NOTE:
1. The ENABLE input must be connected to a valid logic level for proper operation of the SA5200.
LIMITS
UNITS
MIN TYP MAX
4 5.0 9.0 V
6.4 8.4 10.4 mA
95 255 µA
17.8 22.2 mA
320 960 µA
1.25 V
2.0
VCC
V
-0.3 0.8 V
-1 0 1 µA
-1 0 1 µA
0.6 0.83 1.0
V
AC ELECTRICAL CHARACTERISTICS1
VCC = +5V, TA = 25°C, either amplifier, enable = 5V; unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS
LIMITS
MIN TYP MAX
S21 Insertion gain
f = 100MHz
f = 900MHz
9.2 11 13.2
5.2 7.5
S22 Output return loss
f = 900MHz
–14.3
S12 Reverse isolation
f = 900MHz
–17.9
S11 Input return loss
f = 900MHz
–16.5
P-1 Output 1dB compression point
f = 900MHz
–4.3
NF Noise figure in 50
f = 900MHz
3.6
IP2
IP3
ISOL
Input second-order intercept point
Input third-order intercept point
Amplifier-to-amplifier isolation2
f = 900MHz
f = 900MHz
f = 900MHz
+4.3
–1.8
–25
POUT
S21
Saturated output power
Insertion gain when disabled
f = 900MHz
f = 100MHz
f = 900MHz
–1.7
–13
–13.5
NOTE:
1. All measurements include the effects of the SA5200 Evaluation Board (see Figure 4). Measurement system impedance is 50.
2. Input applied to one amplifier, output taken at the other output. All ports terminated into 50.
UNITS
dB
dB
dB
dB
dBm
dB
dBm
dBm
dB
dBm
dB
1997 Nov 07
5–3





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)