(FRA1001G - FRA1007G) 10 Amps / Glass Passivated Fast Recovery Rectifiers
FRA1001G THRU FRA1007G
10 AMPS. Glass Passivated Fast Recovery Rectifiers
Voltage Range 50 to 1000 Volts Current 10 Ampe...
Description
FRA1001G THRU FRA1007G
10 AMPS. Glass Passivated Fast Recovery Rectifiers
Voltage Range 50 to 1000 Volts Current 10 Amperes
Features
Low forward voltage drop High current capability High reliability High surge current capability
TO-220A
.185(4.70) .175(4.44) .412(10.5) MAX DIA .154(3.91) .148(3.74) .27(6.86) .23(5.84) .594(15.1) .587(14.9) .055(1.40) .045(1.14)
.113(2.87) .103(2.62)
Mechanical Data
Cases: ITO-220AC molded plastic Epoxy: UL 94V-0 rate flame retardant Terminals: Leads solderable per MIL-STD-202, Method 208 guaranteed Polarity: As marked High temperature soldering guaranteed: 260℃/10 seconds .16”,(4.06mm) from case. Mounting position: Any Weight: 2.24 grams
.16(4.06) .14(3.56) .037(0.94) .027(0.68)
PIN1
2 .11(2.79) .10(2.54)
.56(14.22) .53(13.46)
.205(5.20) .195(4.95)
.025(0.64) .014(0.35)
PIN 1 PIN 2 CASE
Case Positive
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol FRA FRA FRA Type Number
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current @TC = 100℃ Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method ) Maximum Instantaneous Forward Voltage @ 10A Maximum DC Reverse Current @ TC=25℃ at Rated DC Blocking Voltage @ TC=125℃ ...