FIBER OPTIC RECEIVING MODULE
TORX170
FIBER OPTIC RECEIVING MODULE
TORX170
FIBER OPTIC RECEIVING MODULE FOR SIMPLEX DIGITAL SIGNAL TRANSMISSION
l Dat...
Description
TORX170
FIBER OPTIC RECEIVING MODULE
TORX170
FIBER OPTIC RECEIVING MODULE FOR SIMPLEX DIGITAL SIGNAL TRANSMISSION
l Data rate: DC to 6 Mb / s (NRZ code) l Transmission distance: Up to 40 m (APF) Up to 1000 m (PCF) l TTL Interface l ATC (Automatic Threshold Control) Circuit is used for stabilized output at a wide range of optical power level. Unit: mm
1. Maximum Ratings (Ta = 25°C)
Characteristics Storage Temperature Operating Temperature Supply Voltage Low Level Output Current High Level Output Current Soldering Temperature Symbol Tstg Topr VCC IOL IOH Tsol Rating −40 to 70 −40 to 70 −0.5 to 7 20 −1 260 (Note 1) Unit °C °C V mA mA °C
Note 1: Soldering time ≤ 3 s (More than 1 mm apart from the package).
2. Recommended Operating Conditions
Characteristics Supply Voltage High Level Output Current Low Level Output Current Symbol VCC IOH IOL Min 4.75 ― ― Typ. 5.0 ― ― Max 5.25 −60 1.2 Unit V µA mA
1
2001-08-10
TORX170
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
Characteristics Data Rate Transmission Distance Symbol NRZ code Test Condition (Note 2) Min DC 0.2 0.2 −55 −15 −18 ― ― ― IOH = −60 µA IOL = 1.2 mA 4.6 ― Typ. ― ― ― ― ― ― ― ― 18 ― ― Max 6 40 1000 55 ― ― −27 −30 30 ― 0.4 Unit Mb / s m m ns dBm dBm dBm dBm mA V V
Using APF (Note 3), TOTX170A Using PCF (Note 4), TOTX170 (Note 5) ∆tw Pulse width 165 ns Pulse cycle 330 ns CL = 10 pF 6 Mb / s, APF, TOTX170A 6 Mb / s, PCF, TOTX170 6 Mb / s, APF, TOTX170A 6 Mb / s, PCF, TOTX170
Pulse Width Distortion Max...