Document
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
108-98011 Rev. C
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
108-98011 • Nov. 07 Rev. C • ECOC: JM10
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
Dimensions DIP version (high)
DIP-high version
mm inch
L 19.30 - 0.2
0.760 - 0.008
W 7.00 - 0.2
0.276 - 0.008
H 7.50 - 0.2
0.295 - 0.008
S 0.50 ± 0.1
0.200 ± 0.004
T 3.20 ± 0.1
0.126 ± 0.004
Tw 0.50 ± 0.1
0.020 ± 0.004
Tz 0.25 ± 0.1
0.010 ± 0.004
108-98011 Rev. C
Dimensions in mm
Mounting hole layout Top view
Terminal assignment Top view
2 form a standard
1 form c with diode
B000
C010
2 form a with diode
B010
1 form c with electrostatic shield and diode
C011
All specifications subject to change. Consult Tyco Electronics for latest specifications.
6 of 13
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
Coil Data (values at 23 °C)
108-98011 Rev. C
Ordering Information
Nominal voltage
Unom
Vdc
Operate/set voltage range
Minimum voltage Umin
Vdc
Maximum voltage Umax
Vdc
Release/ reset voltage
Minimum
Vdc
Coil power
mW
DIP version high: 2 form a contact, standard
5 3.5 12 8.4 15 10.5 24 16.8
14 25 47 47
0.75 1.80 2.25 3.60
125 288 112 288
DIP version high: 2 form a contact, with diode
5 3.5 12 8.4 15 10.5 24 16.8
14 25 47 47
0.75 1.80 2.25 3.60
125 288 112 288
DIP version high: 1 form c contact, with diode
5 3.5 14.5 12 8.4 23.5 15 10.5 14.5 24 16.8 49.0
0.75 1.80 2.25 3.60
125 288 112 288
DIP version high: 1 form c contact, with diode and electrostatic shield
5 3.5 14.5 12 8.4 23.5 15 10.5 14.5 24 16.8 49.0
0.75 1.80 2.25 3.60
125 288 112 288
Coil Resistance
Relay code
Tyco part number
Ω / ± 10 %
200 500 2000 2000
200 500 2000 2000
200 500 2000 2000
200 500 2000 2000
V23100-V4305-B000 V23100-V4312-B000 V23100-V4315-B000 V23100-V4324-B000
1-1393763-8 2-1393763-6 3-1393763-2 3-1393763-8
V23100-V4305-B010 V23100-V4312-B010 V23100-V4315-B010 V23100-V4324-B010
1-1393763-9 2-1393763-7 3-1393763-3 3-1393763-9
V23100-V4305-C010 V23100-V4312-C010 V23100-V4315-C010 V23100-V4324-C010
2-1393763-2 3-1393763-0 3-1393763-6 4-1393763-2
V23100-V4305-C011 V23100-V4312-C011 V23100-V4315-C011 V23100-V4324-C011
2-1393763-3 3-1393763-1 3-1393763-7 4-1393763-3
Ambient temperature tamb [°C]
UI = UII =
Minimum voltage at 23 °C after preenergizing with nominal voltage without contact current
Maximum continous voltage at 23 °C
The operating voltage limits UI and UII depend on the temperature according to the formula:
UI tamb =
and
UII tamb =
tamb
=
UI tamb =
UII tamb =
kI , kII =
KI · UI 23 °C
KIl · UIl 23 °C Ambient temperature Minimum voltage at ambient temperature, tamb Maximum voltage at ambient temperature, tamb Factors (dependent on temperature), see diagram
All specifications subject to change. Consult Tyco Electronics for latest specifications.
7 of 13
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
108-98011 Rev. C
Contact Data
Type of relay Type of contact/s Contact material Maximum continuous current Maximum switching current Maximum switching voltage at nominal voltage: 5 Vdc
12-24 Vdc Maximum switching capacity DC voltage AC voltage Initial contact resistance / measuring condition: Electrical endurance at 12 V / 10 mA
at 24 V / 400 mA
Insulation
Insulation resistance at 500 Vdc Dielectric test voltage (1 min) contact / coil contact / contact
1 form a
DIP version 2 form a
1A 0.5 A
200 Vdc / Vac peak 200 Vdc / Vac peak
10 W 10 VA
1 form c Ruthenium 1.2 A 0.25 A
SIL version 1 form a
1A 0.5 A
Mini SIL Version 1 form a
1A 0.5 A
175 Vdc
200 Vdc / Vac 200 Vdc / Vac peak
175 Vdc peak 200 Vdc / Vac 200 Vdc / Vac peak
3W 3 VA
10 W 10 VA
10 W 10 VA
<150 mΩ
5 x 107 5 x 106
1500 Vdc 250 Vdc
contact coil > 109Ω
1500 Vdc 200 Vdc
1500 Vdc 250 Vdc
1500 Vdc 225 Vdc
High Frequency Data
Capacitance between coil and contacts between adjacent contact sets between open contacts
General Data
max. 2 pF max. 1 pF max. 1 pF
Type of relay Type of contact/s Maximum operate time (including bounce) Maximum release time Operating temperature range Storage temperature Thermal resistance Maximum permissible coil temperature Vibration resistance (function)
Shock resistance, half sinus, 11 ms Degree of protection Mounting position Resistance to soldering heat
DIP version
SIL version
1 form a
2 form a
1 form c
1 form a
0.75 ms
1.1 ms
0.75 ms
0.15 ms
1.6 ms
0.15 ms
-40 °C ... +85 °C
-40 °C ... + 95 °C
Approx. 75 K / W
105 °C
30 G 10 to 2000 Hz
30 G
30 G
50 to 2000 Hz 10 to 2000 Hz
150 G
50 G
150 G
immersion cleanable, IP 67
any
265 °C / 10 s
Mini SIL Version 1 form a 0.75 ms 0.15 ms
30 G 10 to 2000 Hz
50 G
All specifications subject to change. Consult Tyco Electronics for latest specifications.
11 of 13
.