Micrel, Inc.
2-BIT 8:1 MULTIPLEXER
SY10E163
SY1S0YE10106E3163 SY100E163
FEATURES
s 850ps max. propagation delay s Extended 100E VEE range of –4.2V to –5.5V s Differential outputs s Internal 75KΩ input pulldown resistors s Fully compatible with industry standard 10KH,
100K ECL levels s Fully compatible with Motorola MC10E/100E163 s Available in 28-pin PLCC package
DESCRIPTION
The SY10/100E163 offer two 8:1 multiplexers designed for use in new, high-performance ECL systems. The E163 has differential outputs and common select inputs. The select inputs (SEL0, SEL1, SEL2) determine which one of the eight data inputs (A0–A7, B0–B7) is propagated to the output.
BLOCK DIAGRAM
A0 A1 A2 A3
A4 A5 A6 A7
SEL0 SEL1 SEL2
TO SIDE B
QA QA
PIN NAMES
Pin A0–A7 B0–B7 SEL0, 1, 2 QA, QB QA, QB VCCO
Function A Data Inputs (D) B Data Inputs (D) Select Inputs True Outputs Inverting Outputs VCC to Output
M9999-032006
[email protected] or (408) 955-1690
1
Rev.: E
Amendment: /0
Issue Date: March 2006
Micrel, Inc.
SY10E163 SY100E163
PACKAGE/ORDERING INFORMATION
B1 B0 SEL0 VEE SEL1 SEL2 A0
B2 B3 B4 B5 B6 B7 VCCO
25 24 23 22 21 20 19
26 18
27 17
28
PLCC
16
1
TOP VIEW
15
2
J28-1
14
3 13
4 12 5 6 7 8 9 10 11
A1 A2 A3 A4 A5 A6 A7
28-Pin PLCC (J28-1)
Ordering Information(1)
QB QB VCC NC VCCO QA QA
Part Number SY10E163JC SY10E163JCTR(2) SY100E163JC SY100E163JCTR(2) SY10E163JZ(3)
Package Type J28-1 J28-1 J28-1
J28-1
J28-1
SY10E163JZTR(2, 3) J28-1
SY100E163JZ(3)
J28-1
SY100E163JZTR(2, 3) J28-1
Operating Range
Commercial Commercial Commercial Commercial Commercial
Commercial
Commercial
Commercial
Package Marking SY10E163JC
SY10E163JC SY100E163JC
SY100E163JC
SY10E163JZ with Pb-Free bar-line indicator
SY10E163JZ with Pb-Free bar-line indicator
SY100E163JZ with Pb-Free bar-line indicator
SY100E163JZ with Pb-Free bar-line indicator
Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb Matte-Sn
Matte-Sn
Matte-Sn
Matte-Sn
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
Micrel, Inc.
TRUTH TABLE
SEL2 L L L L H H H H
SEL1 L L H H L L H H
SEL0 L H L H L H L H
A/B Data
0 1 2 3 4 5 6 7
SY10E163 SY100E163
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
Min. Typ. Max.
IIH Input HIGH Current
— — 150
IEE Power Supply Current 10E — 73 88
100E — 73 88
TA = +25°C Min. Typ. Max. — — 150
— 73 — 73
88 88
TA = +85°C Min. Typ. Max. — — 150
— 73 88 — 83 100
Unit µA mA
Condition — —
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
tPD Propagation Delay to Output
D 400 550 800 400 550 800 400 550 800
SEL0
525 725 950 525 725 950 525 725 950
SEL1
425 625 850 425 625 850 425 625 850
SEL2
350 525 725 350 525 725 350 525 725
tskew
Within-Device Skew An, Bn to Q An, Am to QA Bn, Bm to QB
— 40 — — 40 — 30 — — 30 — 30 — — 30
— — 40 — — 30 — — 30
— — —
tr Rise/Fall Time tf 20% to 80%
275 375 575 275 375 575 275 375 575
Note: 1. Within-device skew is defined as identical transition on similar paths through a device; n = 0-7, m ≠ n, m = 0-7.
ps ps ps
Condition —
1
—
M9999-032006
[email protected] or (408) 955-1690
3
Micrel, Inc.
28-PIN PLCC (J28-1)
SY10E163 SY100E163
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690