T92 Power Relay
General Purpose Relays
Power Relay T92
I I I I I I I I
2 pole 30 A, 2 CO or 2 NO contacts High switching capacity up ...
Description
General Purpose Relays
Power Relay T92
I I I I I I I I
2 pole 30 A, 2 CO or 2 NO contacts High switching capacity up 30 A / 400 VAC DC- or AC coil 4 kV / 8 mm coil-contact Insulation to VDE 0631 and VDE 0700 PCB- or quick connect terminals or chassis mount Adapter for DIN-rail mounting RoHS compliant (Directive 2002/95/EC) as per product date code 0509
Applications Power supplies, heating & ventilation, control equipment
Approvals
V REG.-Nr. 5386 (addl. mounting version 5 in preperation), U E22575, C LO15734 Technical data of approved types on request
Contact data
Contact configuration 2 NO contacts 2 CO contacts Contact set single contact Type of interruption micro disconnection Rated current NO contact (PCB / flange mount) 30 / 25 A 30 / 25 A NC contact 3A Rated voltage / max.switching voltage AC 400 / 600 VAC Maximum breaking capacity AC, NO / NC contact 12 kVA 12 / 1.2 kVA Contact material AgCdO Minimum contact load 500mA, 12V Mechanical endurance >5x106 cycles Rated frequency of operation with / without load 14 min-1 / 120 min-1 Contact ratings Type NO contacts, PCB version NO contacts, flange mount version NO / NC contacts, all versions NO / NC contacts, all versions
Coil data
Rated coil voltage range DC coil AC coil Coil power DC coil AC coil Operative range
w
w
w
Load 30 A @ 400 VAC 25 A @ 400 VAC 25 A / 3 A @ 400 VAC 20 A / 3 A @ 28 VDC
t a .D
S a
e h
U 4 t e
.c
m o
F0167-A
Cycles 1x105 1x105 3x104 1x105
5...110 VDC 24...240 VAC 1700 mW 4 VA 1