DatasheetsPDF.com

POL-30030 Dataheets PDF



Part Number POL-30030
Manufacturers Premier
Logo Premier
Description Flyback Transformer Control
Datasheet POL-30030 DatasheetPOL-30030 Datasheet (PDF)

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 O C FIGURE 1: SCHEMATIC DIAGRAM SWITCHING TRANSFORMER DESIGNED FOR USE WITH POWER INTEGRATIONS PWR-TOP227Y. REFER TO APPLICATION CIRCUITS OF FIGURE 3. SPEC LIMITS TYP. 750 WHITE DOT DENOTES PIN #1 (HOT RAIL) 1 PRIMARY (DRAIN) 3 (+BIAS) 5 BIAS (HOT RETURN) 6 SECONDARY PINS #12 & 11, #8 & 7 MUST BE RESPECTIVELY CONNECTED TOGETHER FOR PROPER OPERATION. I.E. CONNECTED AS ONE PARALLEL WINDING. 7,8 (+30V RETURN) 11,12 (+30V) PARAMETER PRIMARY INDUCTANCE (3.

  POL-30030   POL-30030



Document
TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 O C FIGURE 1: SCHEMATIC DIAGRAM SWITCHING TRANSFORMER DESIGNED FOR USE WITH POWER INTEGRATIONS PWR-TOP227Y. REFER TO APPLICATION CIRCUITS OF FIGURE 3. SPEC LIMITS TYP. 750 WHITE DOT DENOTES PIN #1 (HOT RAIL) 1 PRIMARY (DRAIN) 3 (+BIAS) 5 BIAS (HOT RETURN) 6 SECONDARY PINS #12 & 11, #8 & 7 MUST BE RESPECTIVELY CONNECTED TOGETHER FOR PROPER OPERATION. I.E. CONNECTED AS ONE PARALLEL WINDING. 7,8 (+30V RETURN) 11,12 (+30V) PARAMETER PRIMARY INDUCTANCE (3-1) VOLTAGE = 0.250Vrms FREQUENCY = 100 KHZ TURN RATIO'S: SEC (11,12-7,8) : PRIMARY (3-1) BIAS (5-6) : PRIMARY (3-1) PRI LEAKAGE IND. (SEC SHORTED) VOLTAGE = 0.250Vrms FREQUENCY = 100 KHZ HIPOT: 50/60Hz, 1 Minute Minimum PRIMARY TO SECONDARY BIAS TO SECONDARY FIGURE 3 CIRCUIT PARAMETERS: (1) AC LINE VOLTAGE 47/400 Hz OUTPUT VOLTAGE OUTPUT CURRENT CONTINUOUS OUTPUT CURRENT PEAK LINE REGULATION (85 TO 265Vac) LOAD REGULATION 10-100% RIPPLE MIN. 675 MAX. 825 UNITS µHY ---------------------- 1:4.000 1:9.333 8.5 --------------12.0 + 4% + 4% µHY SECONDARY 3750 3750 85 0.10 ----------------------------- ---------------------30.0 --------------0.20 0.20 50.0 --------------265 3.00 3.20 ---------------------- Vrms Vrms Vac Vdc Amps Amps +% +% +mV (1) REFER TO APPLICATION CIRCUIT OF FIGURE 3A. FOR 28.0V @ 4.0A, VOLTAGE DOUBLER VERSION REFER TO FIGURE 3B. NOTE1: REINFORCED INSULATION SYSTEM, UL1950, IEC950, CSA-950: A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS B) TRIPLE BASIC INSULATED SECONDARY. C) DESIGNED TO MEET >6.2mm CREEPAGE REQUIREMENTS. D) VARNISH FINISHED ASSEMBLY. E) UL1950 & CSA-950 CERTIFIED: FILE #E162344. F) UL CLASS (B) 130 INSULATION SYSTEM PM130-R1, PM130-H1, PM130-H1A (UL FILE #E177139) OR ANY UL AUTHORIZED CLASS (B) INSULATION SYSTEM. FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES) 12 11 10 9 8 7 P POL-30030 M YYWW PIN #1 WHITE DOT 1 2 3 4 5 6 29.00 (1.142) MAX 34.30 (1.350) MAX CORE TAPED 32.00 (1.260) MAX UL INSULATION SYMBOL AND MANUFACTURER IDENTIFICATION HERE 1 2 3 5.00 (.197) 4 5 6 4.0 (.157) MIN 22.5 (.886) REV. 07/18/97 05/20/98 03/05/99 04/20/99 01/06/04 0.8 DIA. (.032) 25.00 (.984) EI33/29/13 -OR- EI33, 12-PIN VERTICAL BOBBIN UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM DIMENSIONAL TOLERANCES ARE: DECIMALS ANGLES .X + .25 + 0 O 30' .XX + .15 DO NOT SCALE DRAWING DESCRIPTION OF CHANGES UPDATED RELEASE ADDED SECOND APPLICATION CIRCUIT FIG. 3B & UL/CSA APPROVALS UPDATED TO UL CLASS (B) INSULATION SYSTEM CHANGED LEAKAGE INDUCTANCE FROM 16.0 MAX TO 12.0 MAX CORRECT PART NUMBER ON PAGE 2 & 3 www.DataSheet4U.com BY TO TO MD MD PP www.DataSheet4U.com FLYBACK TRANSFORMER CONTROL DRAWING PREMIER P/N: POL-30030 REVISION: 01/06/04 DRAWN BY:PETER PHAM REF: PWR-TOP227Y SCALE: NONE SHEET: 1 OF 7 Premier Magnetics POL-30030 Switch Mode Transformer was designed for use with Power Integrations, Inc. PWRTOP204YAI three terminal off-line PWM switching regulator in the Flyback Buck-Boost circuit configuration. This conversion topology can provide isolated multiple outputs with efficiencies up to 90%. Premiers P0L-30030 transformer has been optimized to provide maximum power throughput. The PWR-TOPXXX series from Power Integrations, Inc. are self contained 100KHz three terminal voltage controlled PWM switching regulators. This series contains all necessary functions for an off-line switched mode control DC power source. These switching regulators provide a very simple solution to off-line designs. The inductors and transformer used with the PWR-TOPXXX are critical to the performance of the circuit. They define the overall efficiency, output power and overall physical size. Below is a universal input high precision 90 watt application circuit utilizing Power Integrations PWR-TOP227 switching regulator in the flyback buck-boost configuration. The component values listed are intended for reference purposes only. Properly sized heat sinks for the TOP227Y & D3 as well as proper thermal management & board layout are critical requirements for efficient and reliable operation. FIGURE 3: TYPICAL APPLICATION CIRCUIT PREMIER MAGNETICS PART NUMBERS: (REQUEST DATA SHEETS BY PART#) L1 = PMCE-0160 16mHy 1.5A EMI/RFI CMC T1 = POL-30030 MAIN SWITCHING TRANSFORMER L2 = VTP-01002 [email protected]([email protected]) INDUCTOR F1 3.1A 250v LINE 85-265Vac 50/60Hz NEUT APPLICATION NOTES ALUMINUM ELECTROLYTIC FILTER CAPACITOR RATINGS: C1: > 400V, Ripple Rated > 790mA @ 120Hz @ Max. Operating Temp. (Nichicon P/N LLQ2G471MHSC, 85C) C2, C3: > 50V, IN PARALLEL Ripple Rated > 3500mA @ 100KHz @ Max. Op. Temp. (Panasonic P/N EEUFA1H102L, 105C) EMI FILTER 1 C6 0.1uF L1 PMCE-0160 16mHY BR1 2KBP04M 400V, 2 .0A 2 ~ + HOT RAIL +100 to 375Vdc C1 470 uF 400V 4 C6 = 0.1uF 250Vac X2-Saftey Cap 3 ~ - C1, 470.0 uF, 400V Nichicon # LLQ2G471MHSC, 85C Diameter=35mm (1.378) Length=40mm (1.575) + 1 PRI T1 POL-30030 VR1 = VR2 1N6298A (1.5KE130A) D1 MUR160 D3 MUR620 L2 VTP-01002 8uH @ 4.0A 1 1/2 OF U3 A C 2 11,12 PROPERLY SIZ.


H8S2378 POL-30030 NV-MV21GN


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)