DatasheetsPDF.com

WU Series. WU100 Datasheet

DatasheetsPDF.com

WU Series. WU100 Datasheet






WU100 Series. Datasheet pdf. Equivalent




WU100 Series. Datasheet pdf. Equivalent





Part

WU100

Description

(WU Series) 10/15 Watts WU Series

Manufacture

XP

Datasheet
Download WU100 Datasheet


XP WU100

WU100; ( DataSheet : www.DataSheet4U.com ) DC/ DC Converters XPiQ inc. Intelligent De sign Quality Product 10/15 Watts WU Se ries • 4:1 Input Range • Isolated O utputs • Efficiency to 84% • Overvo ltage Protection • Input π Filter Short Circuit Protected • Fully Reg ulated Outputs Specification All speci fications are typical at nominal line, full load and 25°C Input Input V.


XP WU100

oltage Range Input Filter • • See Ta ble π Network General Switching Frequ ency Efficiency Isolation (Input-Output ) • • • 100 kHz See Table 500 VDC (1000 Mohm/80pF) Output Voltage Accur acy Line Regulation (Full Input Range) Load Regulation (1/4-full load) Ripple & Noise (DC-20 MHz) Temperature Coeffic ient Short Circuit Protection • • • • • ±1.0% max. ±1.0% max. ±1.0.


XP WU100

% max. 1% of Vout max. ±0.02%/°C max. Indefinite Environmental Operating Tem perature Storage Temperature • • -2 5°C to +71°C -55°C to 125°C 25 ww w.XP-iQ.com PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xp-iq.com Hollist on, MA 01746 USA www.DataSheet4U.com • • OUTPUT VOLTAGE & CURRENT RATI NGS Model WU100 WU101 WU102 WU103 WU104 WU105 WU106 WU200 WU201 WU202 W.



Part

WU100

Description

(WU Series) 10/15 Watts WU Series

Manufacture

XP

Datasheet
Download WU100 Datasheet




 WU100
( DataSheet : www.DataSheet4U.com )
XPiQ inc.
Intelligent Design Quality Product
DC/DC Converters
10/15 Watts
WU Series
4:1 Input Range
Isolated Outputs
Efficiency to 84%
Overvoltage Protection
Input π Filter
Short Circuit Protected
Fully Regulated Outputs
Specification
All specifications are typical at nominal line, full load and 25°C
Input
Input Voltage Range
Input Filter
Output
Voltage Accuracy
Line Regulation
(Full Input Range)
Load Regulation
(1/4-full load)
Ripple & Noise
(DC-20 MHz)
Temperature
Coefficient
Short Circuit
Protection
See Table
π Network
±1.0% max.
±1.0% max.
±1.0% max.
1% of Vout max.
±0.02%/°C max.
Indefinite
General
Switching
Frequency
Efficiency
Isolation
(Input-Output)
Environmental
Operating
Temperature
Storage
Temperature
100 kHz
See Table
500 VDC
(1000 Mohm/80pF)
-25°C to +71°C
-55°C to 125°C
25 www.XP-iQ.com
www.DataSheet4U.com
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA





 WU100
OUTPUT VOLTAGE & CURRENT RATINGS
Model
Input
Output
Output
WU100
WU101
WU102
WU103
WU104
WU105
WU106
WU200
WU201
WU202
WU203
WU204
WU205
WU206
WU207
WU208
WU209
WU300
WU301
WU302
WU303
WU304
WU305
WU306
WU307
WU308
WU309
WU400
Voltage
4.5-6.0 VDC
4.5-6.0 VDC
4.5-6.0 VDC
4.5-6.0 VDC
4.5-6.0 VDC
4.5-6.0 VDC
4.5-6.0 VDC
9.0-18.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
9.0-36.0 VDC
18.0-36.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
20.0-72.0 VDC
36.0-72.0 VDC
Voltage
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±5.0 VDC
±12.0 VDC
±15.0 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±5.0 VDC
±12.0 VDC
±15.0 VDC
5.0/±12.0 VDC
5.0/±15 VDC
5.0/+12.0/–5.0 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±5.0 VDC
±12.0 VDC
±15.0 VDC
5.0/±12.0 VDC
5.0/±15.0 VDC
5.0/+12.0/–5.0 VDC
3.3 VDC
Current
3000 mA
2000 mA
800 mA
667 mA
±1000 mA
±400 mA
±333 mA
3000 mA
3000 mA
1250 mA
1000 mA
±1500 mA
±625 mA
±500 mA
1500/±310 mA
1500/±250 mA
1500/310/500 mA
3000 mA
3000 mA
1250 mA
1000 mA
±1500 mA
±625 mA
±500 mA
1500/±310 mA
1500/±250 mA
1500/310/500 mA
3000 mA
Note: Nominal Input Voltage 5,12, 24 or 48 VDC
Mechanical Details
PIN SINGLE
1 + Input
2 - Input
3 + Output
4 Trim
5 - Output
6 Disable
7-
DUAL
+ Input
- Input
+ Output
Common
- Output
Disable
-
TRIPLE
Disable
- Input
+ Input
- Output
Common
5 VDC Output
+ Output
REMOTE ON/OFF CONTROL
Logic Compatibility ................CMOS or Open Collector TTL
Ec - ON,........................................>+5.5 VDC or Open Circuit
Ec - OFF, ..................................................................<1.8 VDC
Shutdown Idle Current ..................................................10 mA
Input Resistance ......................(Ein 0 VDC to 9 VDC)100KOhm
Control Common ........................Referenced to input Minus
EXTERNAL OUTPUT TRIMMING
Output may optionally be externally trimmed (±5%)
with a fixed resistor or an external trimpot as shown.
Input Current
No Load
Full Load
10 mA
2470 mA
10 mA
2620 mA
10 mA
2520 mA
10 mA
2510 mA
10 mA
2620 mA
10 mA
2520 mA
10 mA
2510 mA
10 mA
1030 mA
30 mA
1560 mA
30 mA
1540 mA
30 mA
1525 mA
30 mA
1560 mA
30 mA
1540 mA
30 mA
1520 mA
20 mA
1576 mA
20 mA
1582 mA
20 mA
1447 mA
10 mA
500 mA
20 mA
760 mA
20 mA
750 mA
20 mA
745 mA
20 mA
760 mA
20 mA
750 mA
20 mA
745 mA
15 mA
778 mA
15 mA
781 mA
15 mA
715 mA
10 mA
245 mA
SINGLE/DUAL OUTPUT
WU
%
Efficiency
80
76
76
80
76
76
79
80
80
81
82
80
81
82
79
79
79
83
82
83
84
82
83
84
80
80
80
84
Dimensions in inches (mm).
NOTES:
1. Voltage accuracy on 3VDC and triple outputs ±3% Max.
Single outputs can be trimmed ±5%.
2. Load regulation ±2% for dual and triple outputs.
3. Triple outputs require minimum of 10% load for rated performance.
4. Remote on/off standard on triple output units, add
suffix “E” to part number for option on single and dual output units.
www.XP-iQ.com
TRIPLE OUTPUT
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
26








Recommended third-party WU100 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)