Document
www.DataSheet4U.com
VDE
ULTRA-MINIATURE PC BOARD TYPE POWER RELAY FEATURES
16 .630
JS RELAYS
22 .866
16 .630
mm inch
• Ultra-miniature size with universal terminal footprint • High contact capacity: 10 A • Class B coil insulation type available • TV-5 type available 1 Form A type → TV-5 1 Form C type → TV-5 (N.O. side only) • VDE, TÜV also approved • Sealed construction for automatic cleaning
SPECIFICATIONS
Contact
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Mechanical (at 180 cpm) Electrical at 10 A 125 V AC, Expected 6 A 277 V AC resistive life (at 20 cpm) (min.ope.) 10 A 250 V AC resistive (at 20 cpm) Rating (resistive load) 1 Form A, 1 Form C 100 mΩ
Characteristics
Max. operating speed Initial insulation resistance Initial Between open contacts breakdown Between contacts and coil voltage*1 20 cpm Min. 100 MΩ (at 500 V DC) 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 10 ms Approx. 10 ms Max. 35°C Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} Approx. 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm Approx. 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2 mm –40°C to +85°C –40°F to +185°F 5 to 85% R.H. Approx.12 g .423 oz
Coil
Nominal operating power Remarks
Silver alloy 10 A 250 V AC 10 A 125 V AC Operate time*2 6 A 277 V AC (at nominal voltage) 2,500 VA Release time(without diode)*2 (at nominal voltage) 250 V AC, 100 V DC Temperature rise (at nominal voltage) 10 A (AC), 5 A (DC) Functional*3 7 DataSheet4U.com 10 Shock resistance Destructive*4 105 Functional*5 Vibration 5 × 104 resistance (No contact only) Destructive 360 mW Conditions for operation, Ambient transport and storage*6 temp.*7 (Not freezing and condensHumidity ing at low temperature) Unit weight
* Specifications will vary with foreign standards certification ratings. *1 Detection current: 10mA *2 Excluding contact bounce time *3 Half-wave pulse of sine wave: 11ms; detection time: 10µs *4 Half-wave pulse of sine wave: 6ms *5 Detection time: 10µs *6 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). *7 When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
e DataShe
TYPICAL APPLICATIONS
1. Home appliances Air conditioner, heater, etc. 2. Automotive Power-window, car antenna, door-lock, etc. 3. Office machines PPC, facsimile, etc. 4. Vending machines
DataSheet4U.com
76
DataSheet4U.com DataSheet 4 U .com
www.DataSheet4U.com
JS
ORDERING INFORMATION
Ex. JS 1a F B 12V
Contact arrangement 1: 1 Form C 1a: 1 Form A
Protective construction Nil: Sealed type F: Flux-resistant type
Coil insulation class Nil: Class E insulation B: Class B insulation
Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48 V
UL/CSA, VDE, TÜV approved type is standard. Notes: 1. Standard packing: Carton: 100 pcs. Case: 500 pcs. 2. When ordering TV rated (TV-5) types, add suffix -TV.
COIL DATA
Sealed type JS1a-5V JS1a-6V JS1a-9V JS1a-12V JS1a-18V JS1a-24V JS1a-48V Part No. Flux-resistant type JS1aF-5V JS1aF-6V JS1aF-9V JS1aF-12V JS1aF-18V JS1aF-24V JS1aF-48V 1 Form A 1 Form C 1 Form A JS1-5V JS1-6V JS1-9V JS1-12V JS1-18V JS1-24V JS1-48V
Nominal Pick-up Drop-out Coil Nominal Max. Nominal voltage, voltage, resistance, operating current, operating allowable voltage, V DC (max.) V DC (min.) Ω (±10%) power, mW voltage mA (±10%) 1 Form C V DC (at 20°C68°F) (at 20°C68°F) (at 20°C68°F) (at 20°C68°F) (at 20°C68°F) (at 85°C185°F) JS1F-5V 5 3.5 0.5 69.4 72 JS1F-6V 6 4.2 0.6 100 60 JS1F-9V 9 6.3 0.9 225 40 130%V of JS1F-12V 12 8.4 1.2 400 30 360 nominal voltage JS1F-18V 18 12.6 1.8 900 20 JS1F-24V 24 16.8 2.4 1,600 15 JS1F-48V 48 33.6 4.8 6,400 7.5
mm inch
DIMENSIONS
Schematic (Bottom view) 1a
N.O. 16 .630 0.4 .016 COIL COM
DataSheet4U.com 3.9
.154 0.24 .009 0.8 .031 0.8 .031 COIL 0.4 .016 2 16 .630 1.2 .047 2.3 .091 1 5 4 N.C. 0.4 .016 2 .079 12.2 .480 22 .866 3 N.O. 12 .472
1c
N.O. COM
N.C.
et4U.com
PC board pattern (Copper-side view) 1a
4-1.3 dia. 4-.051 dia.
e DataShe
12 .472
Note: Terminal No. 4 is only for 1 Form C type
General tolerance: ±0.3 ±.012
2 .079
12.2 .480
1c
5-1.3 dia. 5-.051 dia.
12 .472
2 .079
12.2 .480
Tolerance: ±0.1 ±.004
DataSheet4U.com
77
DataSheet4U.com DataSheet 4 U .com
www.DataSheet4U.com
JS
REFERENCE DATA
1. Maximum value for switching capacity
100 Operate/release time, ms 10 Operate time Life, ×104 8 6 4 Release time 2 0 Max. – x Min. Max. – x Min. 120 140 1 0 1 2 3 4 5 6 7 8 9 10 125V AC resistive load
2. Operate/release time
Sample: 25 pcs., JS1-12V
3. Life curve
Ambient temperature: Room temperature
100
Contact current, A
AC resistive load 10
10
1
DC resistive load
10
30
100
80
100
Contact voltag.