HFA240NJ40D Diode Datasheet

HFA240NJ40D Datasheet, PDF, Equivalent


Part Number

HFA240NJ40D

Description

Soft Recovery Diode

Manufacture

International Rectifier

Total Page 5 Pages
Datasheet
Download HFA240NJ40D Datasheet


HFA240NJ40D
www.DataSheet4U.com
PD -2.512 rev. A 02/99
HEXFREDTM
Features
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of
Recovery Parameters
HFA240NJ40D
Ultrafast, Soft Recovery Diode
Anode
1
Cathode
2
Base AC
VR = 400V
VF(typ.)ƒ = 1V
IF(AV) = 240A
Qrr (typ.) = 290nC
IRRM(typ.) = 7.5A
trr(typ.) = 50ns
di(rec)M/dt (typ.)ƒ = 270A/µs
Description
HEXFREDTMdiodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are
ideally suited for power converters, motors drives and other applications
where switching losses are significant portion of the total losses.
TO-244AB
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
EAS
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current 
Non-Repetitive Avalanche Energy ‚
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
400
244
122
900
1.4
460
185
-55 to +150
Units
V
A
mJ
W
C
Thermal - Mechanical Characteristics
Parameter
Min. Typ. Max. Units
RthJC
RthCS
Wt
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Case-to-Sink, Flat, Greased Surface
Weight
––––
––––
––––
––––
––––
––––
0.10
79 (2.8)
0.27
0.14
––––
––––
°C/W
K/W
g (oz)
Mounting Torque „
Mounting Torque Center Hole
Terminal Torque
30 (3.4)
12 (1.4)
30 (3.4)
––––
––––
––––
40 (4.6)
18 (2.1)
40 (4.6)
lbf•in
(N•m)
Vertical Pull
2 inch Lever Pull
––––
––––
––––
––––
80 lbf•in
35
Note:  Limited by junction temperature
‚ L = 100µH, duty cycle limited by max TJ
ƒ 125°C
„ Mounting surface must be smooth, flat, free or burrs or other
protrusions. Apply a thin even film or thermal grease to mounting
surface. Gradually tighten each mounting bolt in 5-10 lbf•in steps
until desired or maximum torque limits are reached. Module
1

HFA240NJ40D
HFA240NJ40D
PD-2.512 rev. A 02/99
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min. Typ. Max. Units
Test Conditions
VBR
Cathode Anode Breakdown Voltage
400 ––– ––– V IR = 100µA
VFM Max Forward Voltage
––– 1.1 1.3
IF = 120A
––– 1.3 1.5 V IF = 240A
See Fig. 1
––– 1.0 1.2
IF = 120A, TJ = 125°C
IRM Max Reverse Leakage Current
––– 1.5 9.0 µA VR = VR Rated
See Fig. 2
––– 2.3 12 mA TJ = 125°C, VR = 320V
CT Junction Capacitance
––– 280 380 pF VR = 200V
See Fig. 3
LS Series Inductance
––– 6.0 ––– nH From top of terminal hole to mounting
plane
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
d i(rec)M /dt1
d i(rec)M /dt2
Parameter
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
Min. Typ. Max. Units
Test Conditions
––– 50 –––
IF = 1.0A, dif /dt = 200A/µs, VR = 30V
––– 77 120 ns TJ = 25°C See Fig.
––– 290 440
TJ = 125°C
5
IF = 120A
––– 7.5 14
––– 16 30
A TJ = 25°C See Fig.
TJ = 125°C
6
VR = 200V
––– 290 780 nC TJ = 25°C See Fig.
––– 2300 6300
TJ = 125°C 7 dif /dt = 200A/µs
––– 320 ––– A/µs TJ = 25°C See Fig.
––– 270 –––
TJ = 125°C
8
80.01 (3.150)
40.26 (1.585)
39.75 (1.565)
2
7.49 (0.295)
DIA.
6.99 (0.275)
(2 PLCS.)
23.55 (0.927)
20.42 (0.804)
34.925 (1.375)
REF.
63.50 (2.500)
60.96 (2.400)
13
92.71 (3.650)
90.17 (3.550)
10.41 (0.410) DIA.
9.65 (0.380)
20.32 (0.800)
17.78 (0.700)
4.95 (0.195) DIA.
4.70 (0.185)
1/4-20 SLOTTED HEX
LEAD ASSIGNMENTS
1 - ANODE
2 - CATHODE
3 - ANODE
15.75 (0.620)
14.99 (0.590)
3.35 (0.132)
3.02 (0.119)
CONFORMS TO JEDEC
OUTLINE TO-244AB
Dimensions in Millimeters and (Inches)
2


Features www.DataSheet4U.com PD -2.512 rev. A 02 /99 HEXFRED Features HFA240NJ40D Anod e 1 Cathode 2 TM Ultrafast, Soft Reco very Diode V R = 400V VF(typ.)ƒ = 1V I F(AV) = 240A Qrr (typ.) = 290nC IRRM(ty p.) = 7.5A trr(typ.) = 50ns di(rec)M/dt (typ.)ƒ = 270A/µs • Reduced RFI an d EMI • Reduced Snubbing • Extensive Characterization of Recovery Parameters Base AC Description HEXFRED diodes a re optimized to reduce losses and EMI/R FI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/ dt simplifies the calculations of losse s in the operating conditions. The soft ness of the recovery eliminates the nee d for a snubber in most applications. T hese devices are ideally suited for pow er converters, motors drives and other applications where switching losses are significant portion of the total losse s. TM TO-244AB Absolute Maximum Ratin gs (per Leg) Parameter VR IF @ TC = 25°C IF @ TC = 100°C IFSM EAS PD .
Keywords HFA240NJ40D, datasheet, pdf, International Rectifier, Soft, Recovery, Diode, FA240NJ40D, A240NJ40D, 240NJ40D, HFA240NJ40, HFA240NJ4, HFA240NJ, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)