DatasheetsPDF.com

ADM200

SMC

Motor Operated Auto Drain

www.DataSheet4U.com 1 Related Products: Motor Operated Auto Drain Series ADM200 Model/Specifications Reliably dischar...


SMC

ADM200

File Download Download ADM200 Datasheet


Description
www.DataSheet4U.com 1 Related Products: Motor Operated Auto Drain Series ADM200 Model/Specifications Reliably discharges even highly viscous drainage Highly resistant to dust and highly viscous drainage, the valve opens and closes reliably to discharge the drainage. Model Fluid Max. operating pressure Proof pressure Ambient and fluid temperature Operating cycle∗ Operating time Power source Power consumption Port size Weight ADM200Air 1.0 MPa 1.5 MPa –5 to 60°C (No freezing) 1 cycle in a minute (Standard) 2 sec./cycle (Standard) 100, 200 VAC 50 60 Hz, Other 4W IN: Rc 3 8 , 1 2 OUT: Rc 3 8 550 g Large drain discharge capacity With a large discharge port, a large amount of drainage can be discharged in a single operation. Elimination of residual drainage from inside of the tank and pipes prevents the generation of foreign matter as a result of dried rust or drainage, which could adversely affect the equipment located on the outlet side. ∗ If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Precautions Be sure to read before handling. Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-146 to 8 for Precautions on every series. Low power consumption: 4 W A long pi...




Similar Datasheet




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)