Miniature Hybrid Multiplier
www.DataSheet4U.com
4000 V Miniature Hybrid Multiplier
0.0 µA - 200.0 µA Output Current 10 Stages
MVM402P10
AC V1 GND...
Description
www.DataSheet4U.com
4000 V Miniature Hybrid Multiplier
0.0 µA - 200.0 µA Output Current 10 Stages
MVM402P10
AC V1 GND V2
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Maximum A.C. Input Voltage Maximum D.C. Output Voltage Maximum D.C. Output Voltage (Two Multipliers in Series) VDC 6000 Typical Output Current Range (1) µA 0.0 - 200.0 Typical Frequency Number of Stages
V PP MVM402P10 900
VDC 4000
kHz 10 - 100 10
Operating Temp: -55°C to +150°C (1) Refer to load lines on next page. .075(1.91) .032(0.81)
Storage Temp: -65°C to +150°C
GND V1 AC
.100(2.54)
Plating: 200-300µin 90/10 tinlead over 50µin nickel.
.580 (14.73)
.465 (11.81) .050(1.27)
AC V2 GND
.100(2.54)
.050(1.27) .100 (2.54)
.350 (8.89)
.730(18.54)
.580 (14.73)
.465 (11.81)
.010 (0.25) .020 (0.51) .050 (1.27) .030(0.76) (6 PL) .180(4.57)
.042 (1.07)
.430 (10.92)
.100 (2.54)
PAD LAYOUT
Dimensions: In. (mm) All temperatures are ambient unless otherwise noted. Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com
1
MVM402P10
5000 4500 Negative Output Voltage Output Voltage (V) (V) 4000 3500
SINGLE MULTIPLIER OUTPUT VOLTAGE VS. INPUT VOLTAGE
10µA
3000 2500
50µA
2000 1500 1000 500 0 100
200µA
100µA
300
500 Input Voltage (Vpp)
700
900
VOUT
MVM402P10 VMI D/C
AC
RL
Typical Single Multiplier Circuit
...