Digit Backlit LCD Module
www.DataSheet4U.com
DPM 500-BL
12.5mm (0.5“) Digit Height Programmable Decimal Points Auto-zero Auto-polarity 200mV d.c...
Description
www.DataSheet4U.com
DPM 500-BL
12.5mm (0.5“) Digit Height Programmable Decimal Points Auto-zero Auto-polarity 200mV d.c. Full Scale Reading (F.S.R.) LED Backlit Annunciators
-+
3½ Digit Backlit LCD Module
The DPM 500-BL uses advanced components and construction techniques to provide a uniquely compact unit. The meter is in a 40 pin DIL integrated circuit format that can be plugged directly into a DIL socket or panel mounted using the snap in bezel.
°C°F
µA
mV kΩ MHz
SCALING
Two resistors Ra and Rb may be fitted in order to alter the full scale reading (F.S.R.) of the meter - see table. Meter will need re-calibration.
Backlit Version
Stock Number
DPM 500-BL
Specification
Required F.S.R.
2V 20V 200V 2kV 200µA 2mA 20mA 200mA
Note Note Note Note
910k 1M 1M 1M 0R 0R 0R 0R
Ra
100k 10k 1k 100R 1k 100R 10R 1R
Rb
Accuracy (overall error)* Linearity Sample rate Operating temperature range Temperature stability Supply voltage Supply current Backlight voltage Backlight current Input leakage current (Vin = 0V)
Min.
Typ.
0.05 3 100 9 150 5 30 1
Max.
0.1 ±1 50 14 60 10
0 7.5
% (±1 count) count sample/sec °C ppm/°C V µA V mA pA
Unit
NOTE Ensure link 10 is cut if fitting Ra.
* To ensure maximum accuracy, re-calibrate periodically.
CONNECTOR SOURCING GUIDE
METHOD 40 Pin DIL IC Socket
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring inputs do exceed 60Vdc, then fi...