CEPT Matching Transformer
www.DataSheet4U.com
CEPT
Matching Transformer
TEW5054
TEW5054 is specifically designed to match a 120 Ω twisted pair...
Description
www.DataSheet4U.com
CEPT
Matching Transformer
TEW5054
TEW5054 is specifically designed to match a 120 Ω twisted pair to a 75 Ω coaxial line in the CEPT trunk. The Longitudinal balance exceeds the requirements of: CCITT I.431.
The Return Loss exceeds the requirements of CCITT G.703 and BS6328.
MECHANICAL
Top view White dot at pin 1
12.2 2.54 (6 places) 10.7
2 75 Ω unbal. 6
0.6 9.1
es)
4 7 120 Ω bal. 1
Recommende foot print 5.5
All dimensions 1.27 are in mm.
nded 1.9
27
2.54 7.62
ELECTRICAL SPECIFICATIONS
TEW5054
TEW5054 (2 - 6) (4 - 1) 75 Ω 120 Ω 1 : 1.26 > 1.0 mH CEPT unbalanced balanced
Line Impedance Turns ratio Inductance Pulse Mask Longitudinal Bal. Return Loss
Pri. Sec.
(2 - 6) : (4 - 1) (4 - 1)
ISSUE: B
95/03/01
(CCITT I.431) (CCITT G.703)
> 40 dB > 12 dB > 18 dB > 14 dB 1500 Vrms
50 - 1544 KHz 50 - 100 KHz 100- 2048 KHz 2048 - 3072 KHz
Dielectric Strength
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel: (613) 226-1626 Fax: (613) 226-7124