Unbonded-Pair Cable. 1590A Datasheet

1590A Cable. Datasheet pdf. Equivalent

Part 1590A
Description Paired - Category 5e Unbonded-Pair Cable
Feature www.DataSheet4U.com 1590A Paired - Category 5e Unbonded-Pair Cable For more information please cal.
Manufacture Belden
Datasheet
Download 1590A Datasheet



1590A
www.DataSheet4U.com
1590A Paired - Category 5e Unbonded-Pair Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 8 for
DataTwist Cables (Modified
Western Electric).pdf
Description:
24 AWG solid bare copper conductors, plenum, FEP Teflon® insulation, twisted pairs, rip cord, see color code chart (below), Flamarrest®
jacket (natural or blue).
SUITABLE APPLICATIONS:
Suitable Applications
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN,
155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU,
Digital Video, RS-422
Number of Pairs
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
2
4
24
Solid
BC - Bare Copper
Insulation Material
FEP - Fluorinated Ethylene Propylene
Pair Color Code Chart :
Number
1
Color
White/Blue Stripe & Blue
Number
2
Color
White/Orange Stripe & Orange
OUTER SHIELD:
Outer Shield Material
OUTER JACKET:
Unshielded
Outer Jacket Material Trade Name
Outer Jacket Material
Outer Jacket Ripcord
OVERALL NOMINAL DIAMETER:
Flamarrest®
LS PVC - Low Smoke Polyvinyl Chloride
Yes
Overall Nominal Diameter
.165 in.
Page 1 of 4



1590A
1590A Paired - Category 5e Unbonded-Pair Cable
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
-20°C To +75°C
21 lbs/1000 ft.
13 lbs.
0.7 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
TIA/EIA Specification
Other Specification
FLAME TEST:
CMP, UL444
CMP
Yes
Yes
01/01/2005
568-B.2 Category 5e
NEMA WC-63.1 Category 5e, UL verified to Category 5e
UL Flame Test
CSA Flame Test
PLENUM/NON-PLENUM:
NFPA 262
FT4, FT6
Plenum (Y/N)
Non-Plenum Number
ELECTRICAL CHARACTERISTICS:
Y
1588A, 1588R
Nom. Mutual Capacitance @ 1 KHz
Maximum Capacitance Unbalance (pF/100 m)
Nominal Velocity of Propagation
Maximum Delay (ns/100 m)
Maximum Delay Skew (ns/100m)
Maximum Conductor DC Resistance @ 20 Deg. C
Maximum DCR Unbalance @ 20 Deg. C
Max. Operating Voltage - UL
14 pF/ft
330 pF/100 m
72 %
538 @ 100MHz ns/100 m
45 ns/100 m
9.38 Ohms/100 m
5%
300 V RMS
ELECTRICAL CHARACTERISTICS - PREMISE:
Premise Cable Electricals Table 1 :
Page 2 of 4





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)