Document
TS2411
Tong Ringer
Pin assignment: 1. Vcc 5. Gnd 2. Rsl 6. Hfo 3. Lfi 7. Hfi 4. Lfo 8. Out
Operating Voltage 13 to 36V Ringing Start Voltage 36V (max.)
General Description
The TS2411 is a bipolar integrated circuit designed for telephone bell replacement.
Features
Designed for Telephone Bell Replacement Low Current Drain Adjustable 2-frequency Tone Adjustable Warbling Rate Extension Tone Ringer Modules Alarms or Other Alerting Devices
Ordering Information
Part No.
TS2411CD TS2411CS
Operating Temp.
o -20 ~ +70 C
Package
DIP-8 SOP-8
www.DataSheet4U.com Adjustable for Reduced Supply Initiation Current.
Built-in hysteresis prevents false triggering and rotary dial ‘Chirps’
Block Diagram
TS2411
1-6
2004/09 rev. B
Absolute Maximum Rating
Description
DC Supply Voltage (Referenced to GND) Power Dissipation in Still Air Plastic DIP Switch Collector Voltage
Symbol
VCC PD Tstg
Value
+ 36 400 -65 to +150
Unit
V mW
o
C
Note: * Maximum Ratings are those values beyond which damage to the device may occur. Functional operation should be restricted to the Recommended Operating Conditions.
Recommended Operating Conditions
Description
Operating Voltage
Symbol
Vopr
Min 13
Max
36
Unit
V
o -45 +65 C Operating Temperature TA Note: This device contains protection circuitry circuitry to guard against damage due to high static voltages or electric fidlds. However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages to this high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range
GND≦(VIN or VOUT)≦Vcc. Unused inputs must always be tied to an appropriate logic voltage level (e.g.,either GND or Vcc). Unused outputs must be left open.
Electrical Characteristics (Voltages Referenced to GND,TA=-20 to +70 oC)
Parameter
Initiation Supply Voltage (1) Initiation Supply Current (1) Sustaining Voltage (1) Sustaining Current High-Level Output Voltage Symbol VSI ISI VSUS ISUS VOH
Test Conditions
See Figure 2 See Figure 2 See Figure 2 See Figure 2 Vcc=21V,IOH=-15mA, Pin6=6V, Pin7=GND Vcc=21V,IOL=15mA, Pin6= GND, Pin7=6V Pin3 =6V, Pin4 =GND, Vcc=21V Pin7 =6V, Pin6 =GND, Vcc=21V
Min
16.8 1.4 9.5 0.7 16.7
Typ
------
Max
21.2 4.2 12.2 2.5 21.0
Unit
V mA V mA V
Low-Level Output Voltage
VOL
---461 576 9.0
-------
1.8 1.0 1.0 563 704 11.0
V μA μA HZ HZ HZ V
Maximun Input Leakage Current
IIN FH1 FH2 FL
High Frequency 1 High Frequency 2 Low Frequency
R3 =191KΩ,C3 =6800pF R3 =191KΩ,C3 =6800pF R2 =165KΩ,C2 =0.47uF
Ringing Start Voltage (4) Vtr See Figure 1 --36 Notes : 1. Initiation supply voltage (VSI) is the supply voltage required to start the tone ringer oscillating. 2. Sustaining voltage (VSUS) is the supply voltage required to maintain oscillation. 3. Ringing start voltage is the value of AC supply voltage required to start the tone ringer ringing in FIG.3 4. This product is not designed for protection against radioactive rays. 5. All data and specific.