2-Line Filters for General-Purpose Applications
Power line filter for single-phase systems Rated voltage 250 V~, 50/60 H...
Description
2-Line Filters for General-Purpose Applications
Power line filter for single-phase systems Rated voltage 250 V~, 50/60 Hz Rated current 1,4 A Construction
s Two-line filter s Plastic case
B84110-B
Features
s High insertion loss s For PCB mounting s Cost-effective solution
Applications
s Low-performance switch-mode power supplies s TV sets s Data systems, small-size equipment, industrial electronics
Terminals
s Pins fitting standard PCB grid www.DataSheet4U.com
Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Circuit diagram
LINE L
LOAD L’
N
N’
SSB0193-6
204 03/01
2-Line Filters for General-Purpose Applications
Technical data Rated voltage V R Rated current IR Test voltage VP Climatic category Weight 250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1414 V–, 2 s (line/line)
B84110-B
In accordance with EN 60068-1 25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test) approx. 47 g
Characteristics and ordering codes IR A 1,4 2 × 0,15 µF (X2) 2 × 27 mH B84110-B-A14 CR LR Ordering code Approvals
565-3
×
× = approval granted
Dimensional drawing
L N 22,5 L’ 27,5 31 N’ 4±1 ø0,8 33 34
SSB0960-9
205 03/01
2-Line Filters for General-Purpose Applications
Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84110-B-A14
80
SSB0195-...
Similar Datasheet