Customer-Specific Filters
Customer-Specific Filters for Base Stations
Power line filters for base stations Rated voltage 250 V–/ 250 V~, 50/60 Hz ...
Description
Customer-Specific Filters for Base Stations
Power line filters for base stations Rated voltage 250 V–/ 250 V~, 50/60 Hz Rated current 16 to 80 A Construction
s Two-line filter s Metal case
B84132-MBS
Features
s s s s
Easy to install Space-saving design High insertion loss up to GHz range Design complies with EN 133200, CSA 22.2 No. 8 1986 s Filter for 50 A: UL 1283 approval s Optimized for use under high climatic stress Applications
s Base stations s Power supplies
www.DataSheet4U.com
Terminals
s Line: Litz wires s Load: Threaded studs
Marking Marking on component: Manufacturer’s logo, ordering code, rated current, rated voltage, rated temperature, date code, terminal assignment, safety approvals Minimum marking on packaging: Manufacturer’s logo, ordering code
316 03/01
Customer-Specific Filters for Base Stations
Circuit diagram
LINE 1 LOAD 1’
B84132-MBS
2
2’
SSB1636-N
Technical data Rated voltage V R Rated current I R Test voltage VP Overload capability Leakage current I leak Climatic category 250 V−/250 V~, 50/60 Hz referred to 60 °C ambient temperature 1700 V– , 2 s (line/line) 1700 V– , 2 s (lines/case) 1,5 · IR for 3 min per hour or 2,5 · IR für 30 s per hour at 250 V~, 50 Hz 25/100/21 (– 25 °C/+100 °C/21 days damp heat test) in accordance with EN 60068-1
Characteristics and ordering codes IR A 16 25 50 80 Terminal cross section mm2 4 4 8,35 25 I leak mA 17 17 17 17 Rtyp mΩ 4,8 2,9 0,8 0,7 Approx. weight kg 0,8 1,0 1,2 1,8 Ordering code
upon request